Conductometric and Potentiometric Titrations
CSIR NET electrochemistry: conductometric titration curves, potentiometric acid–base, redox and precipitation titrations, derivative and Gran plots.
- 19 min
On this page · 15 sections
- Prerequisites
- The Hook: Titrating Without an Indicator
- 1. Conductometric Titrations
- 2. Potentiometric Titrations: The Set-up
- 3. Acid–Base Potentiometric Curves
- 4. Redox Potentiometric Titrations
- 5. Precipitation Potentiometric Titrations
- 6. Locating the End Point
- Memory Tricks
- Don’t Confuse
- Common Mistakes
- Practice
- Quick Revision Table
- Key Takeaways
- What’s Next
Prerequisites
- Conductance and Kohlrausch’s Law: limiting ionic conductivities, especially the very large values for H⁺ and OH⁻.
- Electrochemical Cells and the Nernst Equation: electrode potentials, formal potentials and electrodes of the second kind.
- Ionic Equilibria: pH of weak acids, salts and buffers, and solubility products.
The Hook: Titrating Without an Indicator
1. Conductometric Titrations
The principle
During a titration, ions of the analyte are replaced by ions of the titrant or of the product. Conductance changes according to the difference in ionic conductivities. With the values from the Kohlrausch table (S cm² mol⁻¹ at 25 °C): H⁺ 349.8, OH⁻ 198.6, K⁺ 73.5, Cl⁻ 76.3, NH₄⁺ 73.5, NO₃⁻ 71.4, Ag⁺ 61.9, Na⁺ 50.1, CH₃COO⁻ 40.9.
Practical points:
- Use a titrant about ten times more concentrated than the analyte, so that the volume barely changes; otherwise correct each reading by the factor \( (V_0 + V)/V_0 \).
- Each branch is close to a straight line; points near the end point are curved (by hydrolysis or solubility) and are not used. The end point is the intersection of the extrapolated lines.
- Temperature must be constant (conductance changes by roughly 2% per kelvin).
Strong acid with strong base: HCl + NaOH
$$\text{H}^+ + \text{Cl}^- + \text{Na}^+ + \text{OH}^- \rightarrow \text{Na}^+ + \text{Cl}^- + \text{H}_2\text{O}$$- Before the end point: each mole of NaOH replaces one H⁺ (349.8) with one Na⁺ (50.1). Conductance falls steeply, by about 300 units per mole.
- After: each mole of excess NaOH adds Na⁺ + OH⁻ (50.1 + 198.6 = 248.7). Conductance rises, slightly less steeply.
- Shape: V, with the falling arm the steeper.
Weak acid with strong base: CH₃COOH + NaOH
- At the start: acetic acid is only slightly ionised; conductance is low. The first additions may give a small dip, because acetate formed suppresses the ionisation of the remaining acid (common-ion effect), removing some of the few H⁺ present.
- Before the end point: un-ionised acid is converted to Na⁺ + CH₃COO⁻ (50.1 + 40.9 = 91.0): conductance rises gently.
- After: excess Na⁺ + OH⁻ (248.7): conductance rises steeply.
- End point: the intersection of the gentle and steep rising lines. The break is less sharp than with a strong acid because the salt hydrolyses near the end point.
Weak acid with weak base: CH₃COOH + NH₃
- Before: NH₄⁺ + CH₃COO⁻ form (73.5 + 40.9): conductance rises.
- After: excess NH₃ is barely ionised in the presence of NH₄⁺ (common-ion effect): conductance stays almost flat.
- Shape: rise then plateau. This end point is sharper conductometrically than with any indicator, which is the classic argument for conductometry with weak–weak systems.
Strong acid with weak base: HCl + NH₃
- Before: H⁺ replaced by NH₄⁺ (349.8 → 73.5): falls.
- After: excess NH₃ un-ionised: flat.
Mixture of strong and weak acid: HCl + CH₃COOH with NaOH
NaOH neutralises HCl first (the strong acid suppresses the ionisation of acetic acid), then acetic acid:
- Steep fall (H⁺ → Na⁺) until HCl is used up: first break.
- Gentle rise (CH₃COOH → Na⁺ + CH₃COO⁻) until acetic acid is used up: second break.
- Steep rise (excess NaOH).
The first break gives HCl; the difference between the breaks gives acetic acid. With NH₃ as titrant the last branch is flat instead of rising, and the second break is sharper.
Precipitation: KCl with AgNO₃
$$\text{K}^+ + \text{Cl}^- + \text{Ag}^+ + \text{NO}_3^- \rightarrow \text{AgCl}\downarrow + \text{K}^+ + \text{NO}_3^-$$- Before: Cl⁻ (76.3) is replaced by NO₃⁻ (71.4): conductance nearly flat (slight fall).
- After: excess Ag⁺ + NO₃⁻ (61.9 + 71.4): rises.
A better choice of titrant makes a sharper break: with a titrant whose anion is slower than Cl⁻ (for example silver acetate, if solubility permits), the first branch falls distinctly.
Displacement titrations
A salt of a weak acid titrated with a strong acid: CH₃COONa + HCl → CH₃COOH + NaCl. Before the end point CH₃COO⁻ (40.9) is replaced by Cl⁻ (76.3), so conductance rises slowly; after, excess H⁺ + Cl⁻ makes it rise steeply.
Summary of shapes
| Titration | Before end point | After end point | Shape |
|---|---|---|---|
| HCl with NaOH | steep fall | rise | V |
| CH₃COOH with NaOH | (small dip) gentle rise | steep rise | two rising lines |
| CH₃COOH with NH₃ | rise | flat | rise, plateau |
| HCl with NH₃ | steep fall | flat | fall, plateau |
| HCl + CH₃COOH with NaOH | fall, then gentle rise | steep rise | three branches, two breaks |
| KCl with AgNO₃ | nearly flat | rise | flat, rise |
| CH₃COONa with HCl | slow rise | steep rise | two rising lines |
graph TD
A["Which ion is removed,
which ion replaces it?"] --> B{"Removed ion is H+ or OH-?"}
B -->|"Yes"| C["Steep FALL
(fast ion replaced by slow)"]
B -->|"No"| D{"Ions are created from
un-ionised molecules?"}
D -->|"Yes"| E["RISE
(weak acid or base being neutralised)"]
D -->|"No"| F["Nearly FLAT
(similar ions swapped, e.g. Cl- for NO3-)"]
C --> G["After end point:
excess strong titrant RISES steeply,
excess weak titrant stays FLAT"]
E --> G
F --> GAdvantages: coloured, turbid or very dilute solutions; very weak acids; weak–weak systems; mixtures. Limitation: a large background concentration of unrelated electrolyte swamps the change. Instrumentation is discussed from the analytical side in Electroanalytical Methods.
2. Potentiometric Titrations: The Set-up
An indicator electrode that responds to one species is paired with a reference electrode (SCE or Ag/AgCl), and the cell potential is recorded at zero current after each addition.
| Titration | Indicator electrode | Responds to |
|---|---|---|
| Acid–base | glass electrode (or hydrogen, quinhydrone) | \( a_{\text{H}^+} \) |
| Redox | bright platinum | ratio Ox/Red of the couples present |
| Precipitation (halides with Ag⁺) | silver wire (or Ag/AgCl, Ag₂S ISE) | \( a_{\text{Ag}^+} \) |
| Complexometric (EDTA) | Hg/Hg–EDTA or ion-selective electrode | free metal ion |
Because E is logarithmic, the curve is a sigmoid: flat in buffered regions, with a jump of several hundred millivolts within a fraction of a millilitre at equivalence.
3. Acid–Base Potentiometric Curves
Strong acid with strong base
25.00 mL of 0.100 M HCl with 0.100 M NaOH:
| NaOH added / mL | Species controlling pH | pH |
|---|---|---|
| 0 | 0.100 M H⁺ | 1.00 |
| 12.50 | excess H⁺: 1.25 mmol in 37.5 mL | 1.48 |
| 24.90 | excess H⁺: 0.010 mmol in 49.9 mL | 3.70 |
| 25.00 | water only | 7.00 |
| 25.10 | excess OH⁻: 0.010 mmol in 50.1 mL | 10.30 |
| 30.00 | excess OH⁻: 0.50 mmol in 55 mL | 11.96 |
The pH jumps by about 6.6 units between 24.90 and 25.10 mL. The size of the jump shrinks with dilution: with 0.0010 M solutions it is about two units smaller at each end.
Weak acid with strong base
25.00 mL of 0.100 M CH₃COOH (pKa 4.76) with 0.100 M NaOH:
| Region | Equation | pH |
|---|---|---|
| Start | \( \tfrac12\text{p}K_a - \tfrac12\log c \) | 2.88 |
| Buffer region (5.00 mL) | pKa + log(0.5/2.0) | 4.16 |
| Half-equivalence (12.50 mL) | pH = pKa | 4.76 |
| Equivalence (25.00 mL; 0.0500 M acetate) | \( 7 + \tfrac12\text{p}K_a + \tfrac12\log c \) | 8.73 |
| After (26.00 mL) | excess OH⁻: 0.10 mmol in 51 mL | 11.29 |
Three things to read off such a curve:
- pKa = pH at half-equivalence. This is the standard potentiometric way to measure pKa.
- The equivalence point is above 7 (hydrolysis of acetate). For a weak base with strong acid it is below 7.
- The jump is smaller than for a strong acid and disappears for acids weaker than about \( K_a \approx 10^{-8} \) at 0.1 M. A polyprotic acid gives separate jumps only if successive pKa values differ by roughly 4 units or more (H₃PO₄ gives two usable jumps; the third proton is too weak to show).
4. Redox Potentiometric Titrations
Fe²⁺ titrated with Ce⁴⁺
$$\text{Fe}^{2+} + \text{Ce}^{4+} \rightarrow \text{Fe}^{3+} + \text{Ce}^{3+}$$In 1 M H₂SO₄ the formal potentials are about +0.68 V (Fe³⁺/Fe²⁺) and +1.44 V (Ce⁴⁺/Ce³⁺). After each addition the two couples are at equilibrium, so the platinum electrode reads one common potential, calculated from whichever couple has both members present in known amounts.
| Fraction titrated f | Use | E vs SHE / V |
|---|---|---|
| 0.10 | \( 0.68 + 0.05916\log(0.10/0.90) \) | 0.624 |
| 0.50 | \( E = E^{\circ\prime}_{\text{Fe}} \) | 0.680 |
| 0.90 | \( 0.68 + 0.05916\log 9 \) | 0.736 |
| 0.999 | \( 0.68 + 0.05916\log 999 \) | 0.857 |
| 1.000 | equivalence formula | 1.060 |
| 1.001 | \( 1.44 + 0.05916\log(0.001) \) | 1.263 |
| 2.00 | \( E = E^{\circ\prime}_{\text{Ce}} \) | 1.440 |
The jump from 0.1% before to 0.1% after the equivalence point is about 0.41 V.
Potential at the equivalence point
For \( n_2\,\text{Red}_1 + n_1\,\text{Ox}_2 \rightarrow n_2\,\text{Ox}_1 + n_1\,\text{Red}_2 \), with no H⁺ in the half-reactions, write the Nernst equation for both couples (couple 1: Ox₁ + n₁e⁻ → Red₁, the analyte; couple 2: Ox₂ + n₂e⁻ → Red₂, the titrant), multiply each by its n and add:
$$(n_1 + n_2)E = n_1E_1^{\circ\prime} + n_2E_2^{\circ\prime} - 0.05916\log\frac{[\text{Red}_1][\text{Red}_2]}{[\text{Ox}_1][\text{Ox}_2]}$$At equivalence the stoichiometry gives \( [\text{Ox}_1] = (n_2/n_1)[\text{Red}_2] \) and \( [\text{Red}_1] = (n_2/n_1)[\text{Ox}_2] \), so the quotient is exactly 1 and the log term vanishes:
$$\boxed{E_{\text{eq}} = \frac{n_1E_1^{\circ\prime} + n_2E_2^{\circ\prime}}{n_1 + n_2}}$$where \( n_1 \) and \( n_2 \) are the electrons in the analyte and titrant half-reactions. For Fe²⁺/Ce⁴⁺: \( (0.68 + 1.44)/2 = 1.06 \) V.
When H⁺ takes part, it does not cancel. For Fe²⁺ with MnO₄⁻:
$$E_{\text{eq}} = \frac{E^\circ_{\text{Fe}} + 5E^\circ_{\text{Mn}}}{6} - \frac{8 \times 0.05916}{6}\,\text{pH}$$At pH 0 with standard potentials, \( E_{\text{eq}} = (0.771 + 5 \times 1.51)/6 = 1.387 \) V. The equivalence point is not in the middle of the jump (asymmetric curve) because \( n_1 \neq n_2 \).
Choosing a redox indicator
A redox indicator changes colour over about \( E^{\circ\prime}_{\text{In}} \pm 0.05916/n \) V, so it must have a formal potential inside the steep jump. Ferroin (tris(1,10-phenanthroline)iron(II)) is the usual choice for Fe²⁺/Ce⁴⁺ titrations because its transition potential in acid lies inside the jump, close to the 1.06 V equivalence potential. Diphenylamine sulfonate is used with dichromate.
Feasibility
The equilibrium constant follows from \( \log K = n_1n_2(E_2^{\circ\prime} - E_1^{\circ\prime})/0.05916 \) (for the balanced reaction transferring \( n_1n_2 \) electrons when \( n_1 \) and \( n_2 \) are coprime). For Fe²⁺/Ce⁴⁺, \( \log K = 0.76/0.05916 = 12.8 \). For a quantitative titration (99.9% complete with \( n_1 = n_2 = 1 \)) a difference of formal potentials of about 0.35 V or more is needed (\( K \gtrsim 10^6 \)).
5. Precipitation Potentiometric Titrations
50.0 mL of 0.0500 M Cl⁻ with 0.100 M AgNO₃ (silver indicator electrode; Ksp(AgCl) = \( 1.8 \times 10^{-10} \); E against SHE):
| Ag⁺ added / mL | [Ag⁺] from | E = 0.799 + 0.05916 log[Ag⁺] / V |
|---|---|---|
| 10.0 | \( K_{sp}/[\text{Cl}^-] \), [Cl⁻] = 1.5 mmol/60 mL = 0.025 M | 0.317 |
| 25.0 (equivalence) | \( \sqrt{K_{sp}} = 1.34 \times 10^{-5} \) M | 0.511 |
| 30.0 | excess: 0.50 mmol/80 mL | 0.669 |
The smaller Ksp, the larger the jump. A mixture of I⁻, Br⁻ and Cl⁻ gives three successive jumps (AgI first), because their solubility products differ by several orders of magnitude.
6. Locating the End Point
| Method | What is plotted | End point |
|---|---|---|
| Direct | E (or pH) vs V | midpoint of the steepest part (inflection) |
| First derivative | ΔE/ΔV vs mean V | maximum |
| Second derivative | Δ²E/ΔV² vs V | zero crossing (sign change), interpolated |
| Gran plot | a function linear in V before the end point | intercept on the V axis |
The Gran plot
For a weak acid HA titrated with strong base, in the buffer region \( [\text{H}^+] = K_a[\text{HA}]/[\text{A}^-] = K_a(V_e - V_b)/V_b \). Rearranging:
$$\boxed{V_b\,10^{-\text{pH}} = K_a\,(V_e - V_b)}$$A plot of \( V_b \times 10^{-\text{pH}} \) against \( V_b \) is a straight line with slope \( -K_a \) and intercept \( V_e \) on the volume axis. For a strong acid titrated with base, \( (V_0 + V_b)\,10^{-\text{pH}} \) is plotted in the same way. Gran plots use data away from the equivalence point, so they work for dilute or weak systems where the jump is poorly defined; strictly they assume constant activity coefficients (constant ionic strength).
Memory Tricks
Don’t Confuse
| This | vs | That |
|---|---|---|
| Conductometric: straight lines, end point at intersection | potentiometric: sigmoid, end point at inflection | |
| Conductometry measures all ions | potentiometry measures one activity | |
| E at 50% titrated = \( E^{\circ\prime} \) of the analyte | E at 200% = \( E^{\circ\prime} \) of the titrant | |
| Symmetric redox curve when \( n_1 = n_2 \) | asymmetric when \( n_1 \neq n_2 \) (MnO₄⁻/Fe²⁺) | |
| First derivative: maximum | second derivative: zero crossing | |
| Weak acid + NaOH (conductance keeps rising after end point) | weak acid + NH₃ (flat after end point) |
Common Mistakes
Practice
All questions below are original practice questions written for this page. They are not from any CSIR NET paper. Use 25 °C and 0.05916 V per decade.
Level 1: Foundation
- What is the pH at the half-equivalence point when a weak acid of pKa 4.76 is titrated with NaOH?
- What is the potential at the equivalence point of Fe²⁺ titrated with Ce⁴⁺, if the formal potentials are 0.68 V and 1.44 V?
- Does conductance rise or fall as HCl is titrated with NaOH before the end point?
Answers
- 4.76 (pH = pKa when [HA] = [A⁻]).
- \( (0.68 + 1.44)/2 = \) 1.06 V.
- Falls: fast H⁺ is replaced by slow Na⁺.
Level 2: Part B Style
Practice Q1. In the conductometric titration of acetic acid with aqueous ammonia, the conductance:
(a) falls before the end point and rises after it (b) rises before the end point and stays nearly constant after it (c) stays constant before the end point and rises after it (d) rises before the end point and rises more steeply after it
Answer: (b)
Before: NH₄⁺ and CH₃COO⁻ are formed from two weak electrolytes, so conductance rises. After: excess NH₃ is hardly ionised (common-ion suppression by NH₄⁺), so the line is flat. (d) is the curve for acetic acid with NaOH; (a) for HCl with NaOH; (c) for KCl with AgNO₃.
Practice Q2. Fe²⁺ is titrated with Ce⁴⁺ in 1 M H₂SO₄ (formal potentials 0.68 V and 1.44 V). The potential of the platinum electrode against SHE when 90% of the Fe²⁺ has been oxidised is:
(a) 0.624 V (b) 0.680 V (c) 0.736 V (d) 1.06 V
Answer: (c)
\( E = 0.68 + 0.05916\log(90/10) = 0.68 + 0.0565 = 0.736 \) V. Option (a) inverts the ratio (that is the 10% point).
Practice Q3. The pH at the equivalence point when 25.00 mL of 0.100 M CH₃COOH (pKa 4.76) is titrated with 0.100 M NaOH is:
(a) 7.00 (b) 8.73 (c) 8.88 (d) 9.38
Answer: (b)
At equivalence the volume has doubled: [CH₃COO⁻] = 0.0500 M. pH = 7 + 2.38 + ½log 0.0500 = 7 + 2.38 − 0.65 = 8.73. Option (c) forgets the dilution (uses 0.100 M).
Practice Q4. For the titration of Fe²⁺ with MnO₄⁻ at pH 0 (E° = 0.771 V and 1.51 V), the potential at the equivalence point is about:
(a) 1.14 V (b) 1.39 V (c) 1.51 V (d) 1.26 V
Answer: (b)
\( n_{\text{Fe}} = 1 \), \( n_{\text{Mn}} = 5 \): \( E_{\text{eq}} = (0.771 + 5 \times 1.51)/6 = 8.321/6 = 1.387 \) V. At pH 0 the H⁺ term vanishes. Option (a) is the unweighted average.
Level 3: Part C Style
Practice Q5. 50.0 mL of an HCl solution is titrated conductometrically with 0.500 M NaOH (dilution negligible). The two linear branches are fitted as G = 4.20 − 0.30V before the end point and G = −0.20 + 0.25V after it (G in mS, V in mL). Which statements are correct?
- The end point is at 8.0 mL.
- The HCl concentration is 0.080 M.
- The ratio of the magnitudes of the slopes (falling to rising) is consistent with \( (\lambda_{\text{H}^+} - \lambda_{\text{Na}^+})/(\lambda_{\text{Na}^+} + \lambda_{\text{OH}^-}) \).
- If the acid had been acetic acid of the same concentration, the first branch would also have fallen steeply.
(a) 1, 2 and 3 only (b) 1 and 4 only (c) 2 and 3 only (d) 1, 2, 3 and 4
Answer: (a) 1, 2 and 3 only
- Correct. 4.20 − 0.30V = −0.20 + 0.25V gives 0.55V = 4.40, V = 8.0 mL.
- Correct. \( c = 0.500 \times 8.0/50.0 = 0.080 \) M.
- Correct. Slope ratio 0.30/0.25 = 1.20; ionic conductivities give (349.8 − 50.1)/(50.1 + 198.6) = 299.7/248.7 = 1.21.
- Wrong. Acetic acid is hardly ionised; neutralising it creates Na⁺ + CH₃COO⁻, so the first branch rises gently.
Practice Q6. Near the end point of a redox titration the following potentials were recorded (illustrative data):
| V / mL | 24.70 | 24.80 | 24.90 | 25.00 | 25.10 | 25.20 | 25.30 |
|---|---|---|---|---|---|---|---|
| E / V | 0.810 | 0.830 | 0.870 | 1.010 | 1.180 | 1.230 | 1.250 |
Which statements are correct?
- The first derivative ΔE/ΔV is largest (1.7 V mL⁻¹) in the interval 25.00–25.10 mL.
- The second derivative changes sign between 25.00 and 25.10 mL; linear interpolation puts the end point at about 25.02 mL.
- The end point is at 24.90 mL, where ΔE/ΔV first exceeds 1 V mL⁻¹.
- A Gran plot of these data would need values well before the end point, not these.
(a) 1, 2 and 4 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2, 3 and 4
Answer: (a) 1, 2 and 4 only
ΔE/ΔV (V mL⁻¹) at mid-volumes 24.75, 24.85, 24.95, 25.05, 25.15, 25.25: 0.2, 0.4, 1.4, 1.7, 0.5, 0.2. Maximum 1.7 at 25.05 (statement 1).
Δ²E/ΔV² at 24.90, 25.00, 25.10: (1.4 − 0.4)/0.1 = 10, (1.7 − 1.4)/0.1 = 3, (0.5 − 1.7)/0.1 = −12. Zero crossing between 25.00 (+3) and 25.10 (−12): \( 25.00 + 0.10 \times 3/15 = 25.02 \) mL (statement 2).
Statement 3 confuses a threshold with the inflection. Statement 4 is correct: Gran plots use the linear region away from the end point.
Practice Q7. A weak acid HA was titrated with NaOH. In the buffer region, the following pH values were measured (illustrative data, constant ionic strength):
| \( V_b \) / mL | 10.00 | 12.00 | 16.00 |
|---|---|---|---|
| pH | 5.000 | 5.176 | 5.602 |
Using a Gran plot of \( V_b \times 10^{-\text{pH}} \) against \( V_b \), which pair of results is correct?
(a) \( V_e = 20.00 \) mL, \( K_a = 1.0 \times 10^{-5} \) (b) \( V_e = 16.00 \) mL, \( K_a = 2.5 \times 10^{-6} \) (c) \( V_e = 20.00 \) mL, \( K_a = 1.0 \times 10^{-4} \) (d) \( V_e = 10.00 \) mL, \( K_a = 1.0 \times 10^{-5} \)
Answer: (a)
\( V_b \times 10^{-\text{pH}} \): \( 10.00 \times 1.000 \times 10^{-5} = 1.000 \times 10^{-4} \); \( 12.00 \times 6.67 \times 10^{-6} = 8.00 \times 10^{-5} \); \( 16.00 \times 2.50 \times 10^{-6} = 4.00 \times 10^{-5} \).
Slope = \( (4.00 \times 10^{-5} - 1.000 \times 10^{-4})/6.00 = -1.00 \times 10^{-5} \), so \( K_a = 1.0 \times 10^{-5} \). Intercept on the V axis: \( V_e = 10.00 + 1.000 \times 10^{-4}/1.00 \times 10^{-5} = 20.00 \) mL.
Check: at \( V_b = 10.00 = V_e/2 \), pH = pKa = 5.00, as it should. Option (d) mistakes the half-equivalence volume for \( V_e \).
Quick Revision Table
| Idea | Formula or fact |
|---|---|
| Conductometric end point | intersection of two straight branches |
| HCl + NaOH | steep fall (−299.7), rise (+248.7): V |
| CH₃COOH + NaOH | gentle rise (+91.0), steep rise |
| CH₃COOH + NH₃ | rise, flat: sharpest weak–weak end point |
| HCl + CH₃COOH mixture | fall, gentle rise, steep rise: two breaks |
| KCl + AgNO₃ | nearly flat, rise |
| Strong acid–base jump | pH 3.7 → 10.3 within ±0.1 mL (0.1 M) |
| Weak acid curve | pH = pKa at half-equivalence; equivalence pH > 7 |
| Redox | E(50%) = \( E^{\circ\prime} \) analyte; E(200%) = \( E^{\circ\prime} \) titrant |
| Equivalence potential | \( (n_1E_1 + n_2E_2)/(n_1 + n_2) \); Fe/Ce 1.06 V; MnO₄⁻/Fe 1.387 V at pH 0 |
| Precipitation (AgCl) | E at equivalence = \( 0.799 + 0.05916\log\sqrt{K_{sp}} \) = 0.511 V |
| Derivatives | first: maximum; second: zero crossing |
| Gran (weak acid) | \( V_b10^{-\text{pH}} = K_a(V_e - V_b) \) |
Key Takeaways
What’s Next
- Revise the whole unit on one page: Electrochemistry: Quick Revision.
- Instrumental detail (glass electrode, ISEs, coulometry, polarography): Electroanalytical Methods.
- Back to the start of the unit: Electrochemical Cells, Redox Systems and the Nernst Equation.
- Chapter overview: Electrochemistry.