Skip to content

Activation Analysis

CSIR NET chemistry: neutron activation analysis, activation equation, saturation, comparator method, INAA vs RNAA, interferences and NAA variants.

  • 16 min read
  • Updated
On this page · 17 sections
  1. Prerequisites
  2. The Hook: Making the Sample Announce Itself
  3. The Principle in Four Steps
  4. The Activation Equation
  5. Standardisation: the Comparator Method
  6. Choosing Irradiation, Decay and Counting Times
  7. Instrumental and Radiochemical NAA
  8. Interferences
  9. Neutron Sources and Variants of Activation Analysis
  10. Advantages and Limitations
  11. Memory Tricks
  12. Don’t Confuse
  13. Common Mistakes
  14. Practice
  15. Quick Revision Table
  16. Key Takeaways
  17. What’s Next

Prerequisites

The Hook: Making the Sample Announce Itself

The Principle in Four Steps

graph LR
    A["1. Irradiate
sample + standard
(reactor, n flux φ)"] --> B["2. Decay
(delay t_d: short-lived
matrix activity dies)"] B --> C["3. Count
HPGe γ spectrum
(time t_c)"] C --> D["4. Evaluate
γ energy → element
peak area → mass"]
  1. Irradiation. Sample (and usually a standard) in a neutron flux, mostly thermal neutrons from a research reactor, for a chosen time tᵢ.
  2. Decay. A waiting time t_d lets short-lived interfering activities die away (or, for short-lived products, is kept as short as possible).
  3. Counting. γ spectrometry, usually with a high-resolution HPGe detector.
  4. Evaluation. Each γ photopeak identifies a nuclide and therefore an element; the peak area gives the amount.

Most activation analysis uses (n,γ) capture: the product is a heavier isotope of the same element, typically a β⁻ emitter followed by γ emission from the daughter. Example:

$$^{23}\text{Na}(n,\gamma)\,^{24}\text{Na} \xrightarrow{\beta^-,\ t_{1/2} \approx 15\ \text{h}} {}^{24}\text{Mg} + \gamma$$

The Activation Equation

During irradiation the product is formed at a constant rate R = Nσφ and decays at a rate λN*. So

$$\frac{dN^{*}}{dt} = N\sigma\varphi - \lambda N^{*}$$

and at the end of an irradiation of length tᵢ the activity is

$$\boxed{A_0 = N\sigma\varphi\left(1 - e^{-\lambda t_i}\right) = N\sigma\varphi\,S}$$

where S is the saturation factor. After a decay time t_d,

$$A = N\sigma\varphi\,S\,e^{-\lambda t_d}$$

with N the number of target nuclei:

$$N = \frac{m\,\theta\,N_A}{M}$$

(m = mass of the element, θ = isotopic abundance of the target isotope, M = molar mass of the element).

Saturation

Irradiation time (in half-lives of the product)S = 1 − 2^(−n)
0.50.29
10.50
20.75
30.875
40.94
50.97
∞1.00 (saturation activity Nσφ)

Irradiating for more than three or four half-lives of the product gains little: the activity is already 88–94% of saturation, while long-lived interferences keep growing. For short irradiations (tᵢ ≪ t½), \( S \approx \lambda t_i \), so activity grows linearly with time.

Counts recorded

If the sample is counted for a time t_c with detector efficiency ε and γ emission probability I_γ, the photopeak area is

$$C = \frac{N\sigma\varphi}{\lambda}\,\left(1 - e^{-\lambda t_i}\right)\,e^{-\lambda t_d}\,\left(1 - e^{-\lambda t_c}\right)\,\varepsilon\,I_\gamma$$

The three brackets are the saturation, decay and counting factors. You do not need to memorise the full expression for standard problems, because the comparator method cancels almost everything.

Standardisation: the Comparator Method

Absolute calculation needs φ, σ, ε and I_γ, all with uncertainties. Instead, a standard of known mass of the element is irradiated together with the sample (same flux, same tᵢ) and counted in the same geometry. Everything cancels except the masses and any difference in decay time:

$$\boxed{\frac{m_x}{m_s} = \frac{C_x}{C_s}\cdot\frac{e^{-\lambda t_{d,s}}}{e^{-\lambda t_{d,x}}}}$$

If both are counted after the same delay and for the same time, simply \( m_x = m_s\,C_x/C_s \).

Many laboratories now use a single comparator (often gold) and tabulated nuclear constants for each element, the k₀ method, which allows multi-element analysis without a separate standard for every element.

Choosing Irradiation, Decay and Counting Times

The half-life of the product decides the schedule.

Product nuclide (target)Half-life (approx.)Typical scheme
²⁸Al (²⁷Al)2.24 minshort irradiation (seconds to a minute), count at once
²⁷Mg (²⁶Mg)9.5 minshort
³⁸Cl (³⁷Cl)37 minshort
⁵⁶Mn (⁵⁵Mn)2.58 hshort to medium
⁴²K (⁴¹K)12.4 hmedium
²⁴Na (²³Na)15.0 hmedium; the main matrix nuisance
⁶⁴Cu (⁶³Cu)12.7 hmedium
⁷⁶As (⁷⁵As)26 hmedium
¹⁹⁸Au (¹⁹⁷Au)2.7 dmedium; flux monitor
⁵¹Cr (⁵⁰Cr)27.7 dlong irradiation, delay of weeks
⁵⁹Fe (⁵⁸Fe)44.5 dlong
⁴⁶Sc (⁴⁵Sc)84 dlong
⁶⁰Co (⁵⁹Co)5.27 ylong

A common INAA programme: a short irradiation of one aliquot, counted within minutes for Al, Mg, Cl, Mn, V and similar; a long irradiation of another aliquot, counted after a few days (for As, Na, La, Sm, Au) and again after several weeks, when ²⁴Na has gone (for Co, Cr, Fe, Sc, Zn, Se, the rare earths).

Short-lived products need a short delay because they disappear quickly; a 20-minute wait leaves only about 0.2% of ²⁸Al. Long-lived products need long irradiation because, for tᵢ ≪ t½, S ≈ λtᵢ is small.

Instrumental and Radiochemical NAA

Instrumental NAA (INAA)Radiochemical NAA (RNAA)
Chemistrynone: irradiate, wait, countchemical separation after irradiation
Samplesolid, intact; non-destructivedissolved; destroyed
Strengthfast, multi-element, no reagent blankremoves interfering matrix activity (²⁴Na, ³²P, ⁸²Br); better detection limits for the separated elements
Typical userocks, pottery, hair, reference materialsultra-trace elements in biological tissue and high-purity materials

Interferences

TypeExampleRemedy
Primary interference: another element gives the same product by a different reaction²⁷Al(n,γ)²⁸Al and ²⁸Si(n,p)²⁸Al; ²⁶Mg(n,γ)²⁷Mg and ²⁷Al(n,p)²⁷Mg; ²³Na(n,γ)²⁴Na and ²⁷Al(n,α)²⁴Nawell-thermalised irradiation position (the (n,p) and (n,α) routes need fast neutrons); correct with a pure interferent standard
Second-order reactions: the product itself captures a neutronhigh-flux, long irradiationscorrect or shorten irradiation
Fission interference: uranium in the sample makes fission products⁹⁹Mo, ¹⁴⁰La, rare earths from ²³⁵U fissioncorrect using the uranium content
Spectral interference: overlapping γ peaksclose-lying lines from different nuclideschoose another γ line, HPGe resolution, decay discrimination
Matrix activity: intense lines raise the Compton background²⁴Na, ³⁸Cl, ⁴²K, ³²P in biological samplesdelay, RNAA, anticoincidence counting
Flux perturbation: strong absorbers in the sampleB, Cd, Gd, Lismall samples, internal standards

Neutron Sources and Variants of Activation Analysis

Sources. Research reactors give thermal fluxes typically in the range 10¹²–10¹⁴ n cm⁻² s⁻¹, the basis of the best sensitivity. Isotopic sources (Am–Be, ²⁵²Cf) and D–T neutron generators (14 MeV) are weaker but portable; they are used for major elements and in field or process applications.

VariantNeutrons / particleWhat it addsExamples
Thermal NAAthermalstandard method, highest sensitivity for most elementsNa, Mn, Co, Au, As, rare earths
Epithermal NAA (ENAA)sample shielded by cadmium (or boron), which absorbs thermal neutronsfavours nuclides with large resonance capture, suppresses Na, Cl, Mn matrix activityU, Th, As, Br and others in geological samples
Fast-neutron activation (FNAA)14 MeV (D–T generator)threshold reactions for light elements that thermal (n,γ) missesO by ¹⁶O(n,p)¹⁶N (t½ ≈ 7 s, high-energy γ); N by ¹⁴N(n,2n)¹³N (a β⁺ emitter)
Prompt-gamma NAA (PGNAA)thermal or cold neutron beam; γ rays measured during irradiationelements whose capture product is stable or very short-livedH, B, Cd, Gd, also C, N, S, Si
Charged-particle activation (CPAA)p, d, ³He, α from acceleratorslight elements (C, N, O) at surfaces and in high-purity metals¹²C(d,n)¹³N
Photon activation (PAA)bremsstrahlung from an electron linac(γ,n) reactions¹²C(γ,n)¹¹C, light elements

Boron is the standard PGNAA case: ¹⁰B(n,α)⁷Li leaves ⁷Li in an excited state that emits a prompt γ ray near 478 keV, Doppler-broadened because the lithium is recoiling.

Advantages and Limitations

AdvantagesLimitations
Very sensitive for many elements (ppm to ppb, better with RNAA)Needs a nuclear reactor (or accelerator) for best results
Multi-element: tens of elements from one samplePoor for H, C, N, O and for some heavy elements such as Pb and Bi by thermal (n,γ)
Non-destructive (INAA): sample can be reused or archivedLong turnaround for long-lived products (weeks)
No reagent blank in RNAA; contamination after irradiation is harmlessMatrix activity (Na, Cl, Br, P) can swamp traces
Little matrix effect on the nuclear reaction; neutrons and γ rays penetrate the whole sampleGives total element only, not chemical form (speciation)
Independent of chemical state; ideal for certifying reference materialsRadioactive samples need licensed handling

Where it is used

  • Geochemistry and cosmochemistry: rare-earth patterns of rocks and meteorites; iridium and other platinum-group anomalies.
  • Archaeology: provenance of pottery, obsidian and coins from their trace-element fingerprints, non-destructively.
  • Forensic science: trace elements in hair, glass, paint and gunshot residue (Sb, Ba).
  • Environment and biology: Se, As, Hg, Co and other trace elements in food, tissue and air filters.
  • Materials: impurities at ppb levels in high-purity silicon and other electronic materials.

Memory Tricks

Don’t Confuse

ThisvsThat
Saturation activity Nσφ (tᵢ → ∞)End-of-irradiation activity Nσφ S
INAA: no chemistry, non-destructiveRNAA: post-irradiation separation, destructive
Thermal NAA: (n,γ), most elementsFNAA: 14 MeV threshold reactions, O, N
PGNAA: γ during irradiation (B, H, Cd, Gd)Delayed-γ NAA: γ from the radioactive product after irradiation
Epithermal NAA (Cd-covered)Thermal NAA (bare)
Activation analysis: sample made radioactiveIsotope dilution: label added to the sample
Primary interference (same product nuclide)Spectral interference (different nuclides, overlapping γ lines)

Common Mistakes

Practice

All questions below are original practice questions written for this page. They are not from any CSIR NET paper. Nuclear data given in a question are for that question.

Level 1: Foundation

  1. What fraction of saturation activity is reached after irradiating for two half-lives of the product?
  2. Write the product of ⁵⁹Co(n,γ).
  3. Which variant of NAA measures γ rays during irradiation?
Answers
  1. 1 − (1/2)² = 0.75.
  2. ⁶⁰Co.
  3. Prompt-gamma NAA (PGNAA).

Level 2: Part B Style

Practice Q1. A sample is irradiated for a time equal to three half-lives of the product. The activity at the end of irradiation, as a fraction of the saturation activity, is:

(a) 0.333 (b) 0.750 (c) 0.875 (d) 0.950

Answer: (c)

S = 1 − 2⁻³ = 0.875.

Practice Q2. In neutron activation analysis of a silicon-rich sample for aluminium (via ²⁸Al), the main primary interference comes from:

(a) ²⁸Si(n,γ)²⁹Si (b) ²⁸Si(n,p)²⁸Al (c) ²⁷Al(n,α)²⁴Na (d) ³⁰Si(n,γ)³¹Si

Answer: (b)

²⁸Si(n,p)²⁸Al gives the same product as ²⁷Al(n,γ)²⁸Al. It needs fast neutrons, so a well-thermalised irradiation position reduces it. (a) and (d) give silicon isotopes, not ²⁸Al.

Practice Q3. The main reason radiochemical NAA is free from reagent-blank errors is that:

(a) reagents are radioactive (b) separations are done after irradiation, so inactive contaminants are not counted (c) neutrons destroy impurities (d) no carriers are used

Answer: (b)

Contamination introduced after irradiation is inactive. Carriers are in fact added freely (so (d) is wrong).

Practice Q4. A standard containing 10.0 µg of an element and an unknown are irradiated together and counted under identical conditions after the same delay. The standard gives 5.0 × 10⁴ counts and the unknown 2.0 × 10⁴ counts in the same photopeak. The mass of the element in the unknown is:

(a) 4.0 µg (b) 25 µg (c) 2.5 µg (d) 0.4 µg

Answer: (a)

mₓ = 10.0 × (2.0 × 10⁴/5.0 × 10⁴) = 4.0 µg.

Level 3: Part C Style

Practice Q5. 1.00 µg of sodium (single isotope ²³Na, M = 22.99 g mol⁻¹) is irradiated for 15 h at φ = 1.0 × 10¹² n cm⁻² s⁻¹. Take σ = 0.53 b and t½(²⁴Na) = 15 h. Which statements are correct?

  1. The saturation activity is about 1.4 × 10⁴ Bq.
  2. The activity at the end of irradiation is about 6.9 × 10³ Bq.
  3. Irradiating for 60 h instead would raise the end-of-irradiation activity by a factor of about 1.9.
  4. Irradiating for 150 h instead would raise it by a factor of 10.

(a) 1, 2 and 3 only (b) 1 and 2 only (c) 2 and 4 only (d) 1, 2, 3 and 4

Answer: (a) 1, 2 and 3 only
  1. Nσφ = 2.62 × 10¹⁶ × 0.53 × 10⁻²⁴ × 10¹² = 1.39 × 10⁴ Bq. Correct.
  2. S = 0.5: 6.9 × 10³ Bq. Correct.
  3. 60 h = 4 half-lives, S = 0.9375; ratio 0.9375/0.5 = 1.875. Correct.
  4. 10 half-lives gives S ≈ 0.999, only about twice the one-half-life value, not ten times. Wrong.

Practice Q6. A 5.0 µg Mn standard and a sample are irradiated together. Take t½(⁵⁶Mn) = 2.58 h. The standard, counted 1.0 h after irradiation, gives 40 000 counts; the sample, counted 2.0 h after irradiation for the same counting time, gives 12 000 counts. The Mn content of the sample is closest to:

(a) 1.5 µg (b) 1.7 µg (c) 2.0 µg (d) 2.6 µg

Answer: (c)

λ = 0.2687 h⁻¹. Correct the sample count back by 1.0 h: 12 000 × e^0.2687 = 15 700. mₓ = 5.0 × 15 700/40 000 = 1.96 µg. (a) omits the decay correction.

Practice Q7. A geological sample contains Al, Na, Co and Mn. Which statements are correct?

  1. To determine Al via ²⁸Al (t½ ≈ 2.2 min), the sample should be counted within minutes of a short irradiation.
  2. To determine Co via ⁶⁰Co, a long irradiation and a delay of several weeks, letting ²⁴Na decay, improve the measurement.
  3. An irradiation of 1 h brings ²⁸Al essentially to saturation but ²⁴Na (t½ ≈ 15 h) to only about 4.5% of saturation.
  4. Covering the sample with cadmium increases the ²⁸Al activity from ²⁷Al(n,γ).

(a) 1, 2 and 3 only (b) 1 and 4 only (c) 2, 3 and 4 only (d) 1, 2, 3 and 4

Answer: (a) 1, 2 and 3 only
  1. Correct: after 20 min only (1/2)^(20/2.24) ≈ 0.2% of ²⁸Al remains.
  2. Correct: ²⁴Na dominates the early spectrum; after several weeks it is gone while ⁶⁰Co (5.27 y) is almost unchanged.
  3. Correct: 60/2.24 ≈ 27 half-lives for ²⁸Al (S ≈ 1); for ²⁴Na S = 1 − 2^(−1/15) = 0.045.
  4. Wrong: cadmium removes thermal neutrons, which drive (n,γ) on ²⁷Al; it lowers ²⁸Al production (it is used to suppress thermal activation of matrix elements).

Quick Revision Table

IdeaFact
Principlestable isotope → (n,γ) → radioactive product → γ spectrum identifies, peak area quantifies
ActivationA₀ = Nσφ(1 − e^(−λtᵢ)); A = A₀e^(−λt_d); N = mθN_A/M
Saturation1, 2, 3, 4 half-lives → 50, 75, 87.5, 94%; short tᵢ: S ≈ λtᵢ
Comparatormₓ = m_s(Cₓ/C_s), with decay correction e^(λΔt); k₀ method uses one comparator
Schedulesshort: ²⁸Al 2.24 min, ³⁸Cl, ⁵⁶Mn 2.58 h; medium: ²⁴Na 15 h, ⁴²K, ⁷⁶As, ¹⁹⁸Au; long: ⁵¹Cr, ⁵⁹Fe, ⁴⁶Sc, ⁶⁰Co
INAA vs RNAAnon-destructive, multi-element vs post-irradiation separation, no reagent blank, carriers
Interferences(n,p) on Z + 1 and (n,α) on Z + 2 mimic (n,γ) on Z; fission of U; spectral overlap; ²⁴Na matrix
VariantsENAA (Cd cover), FNAA 14 MeV (O, N), PGNAA (H, B, Cd, Gd), CPAA, PAA
Limitspoor for H, C, N, O (thermal), Pb, Bi; no speciation; needs reactor
Usesrocks, meteorites, pottery provenance, forensics, high-purity Si, trace elements in tissue

Key Takeaways

What’s Next

Advertisement
Advertisement