Radio-analytical Techniques
CSIR NET chemistry: detectors, counting statistics, isotope dilution, radiometric titration, radioimmunoassay, tracers, Szilard–Chalmers and dating.
- 18 min
On this page · 18 sections
- Prerequisites
- The Hook: Weighing What Cannot Be Weighed
- How Radiation Interacts With Matter
- Radiation Detectors
- Counting Statistics
- Isotope Dilution Analysis (IDA)
- Radiometric Titrations
- Radioimmunoassay (RIA)
- Tracers in Chemistry
- Radiometric Dating
- Radiation Units in Brief
- Memory Tricks
- Don’t Confuse
- Common Mistakes
- Practice
- Quick Revision Table
- Key Takeaways
- What’s Next
Prerequisites
- Nuclear Stability and Radioactive Decay: decay law, activity, specific activity and decay modes. Every method here measures an activity.
- Experimental Design, Sampling and Data: mean, standard deviation and error propagation, which counting statistics specialises.
- Separation Methods: precipitation, solvent extraction and ion exchange, the separations that radiochemistry relies on.
- Omics, Fingerprinting, Barcoding and Radiolabelling: the biological side of radiolabels.
The Hook: Weighing What Cannot Be Weighed
How Radiation Interacts With Matter
Detectors work because radiation ionises or excites the material it passes through.
| Radiation | Interaction | Range | Shielding |
|---|---|---|---|
| α | dense ionisation along a short straight track (high linear energy transfer) | a few cm of air; stopped by paper | trivial externally; very hazardous inside the body |
| β⁻, β⁺ | ionisation along a tortuous path; bremsstrahlung for energetic β in heavy materials; β⁺ annihilates to two 511 keV photons | up to metres of air, millimetres of tissue or plastic | low-Z materials (plastic, perspex) first |
| γ, X-rays | photoelectric effect (low energy, high Z), Compton scattering (intermediate), pair production (above 1.022 MeV) | exponential attenuation, no fixed range | high-Z, dense materials (Pb, concrete) |
| Neutrons | nuclear reactions and elastic collisions, no direct ionisation | long | hydrogenous moderator plus absorber (B, Cd) |
For γ spectroscopy the photoelectric effect is what matters: it deposits the whole photon energy in the detector and gives the photopeak used to identify a nuclide. Compton scattering gives the continuous background below it.
Radiation Detectors
| Detector | Principle | Best for | Energy resolution |
|---|---|---|---|
| Ionisation chamber | collects primary ion pairs, no gas multiplication | high activities, dose calibrators | — |
| Proportional counter | gas multiplication, pulse ∝ primary ionisation | α/β discrimination, low-energy X-rays | moderate |
| Geiger–Müller (GM) counter | full avalanche: every event gives the same large pulse | simple counting of β and γ | none (cannot measure energy); long dead time |
| NaI(Tl) scintillator | light pulse ∝ energy, read by a photomultiplier | γ counting with high efficiency | poor to moderate |
| Liquid scintillation counting (LSC) | sample dissolved in a scintillator cocktail; no window to cross | low-energy β emitters: ³H, ¹⁴C, ³⁵S | moderate; suffers from quenching |
| HPGe semiconductor | electron–hole pairs in germanium, cooled with liquid nitrogen | γ spectrometry of mixtures, activation analysis | best (sharp photopeaks) |
| Si(Li), Si surface barrier | as above, in silicon | X-rays, α spectrometry | high |
| Autoradiography / phosphor imaging, film, TLD | latent image or trapped charge | locating labels on gels, tissue; dosimetry | — |
Why LSC for ³H and ¹⁴C: their β particles are so weak (maximum energies of about 18.6 keV for ³H and 156 keV for ¹⁴C) that they would be absorbed by a counter window or by the sample itself. In LSC the emitter and scintillator are mixed at the molecular level. Coloured or chemically interfering samples reduce light output (quenching), which is corrected with internal standards or quench curves.
Counting Statistics
Radioactive decay is random: the number of counts N recorded in a fixed time follows a Poisson distribution (close to Gaussian for large N), with
$$\boxed{\sigma_N = \sqrt{N}} \qquad \text{relative standard deviation} = \frac{1}{\sqrt{N}}$$| Counts N | σ | Relative σ |
|---|---|---|
| 100 | 10 | 10% |
| 2500 | 50 | 2% |
| 10 000 | 100 | 1% |
So the precision depends on the number of counts, not on the count rate or the time separately. To halve the relative error, collect four times as many counts.
Count rates. For N counts in time t, R = N/t and \( \sigma_R = \sqrt{N}/t = \sqrt{R/t} \).
Net rate after background. Errors add in quadrature:
$$R_{\text{net}} = R_g - R_b, \qquad \sigma_{\text{net}} = \sqrt{\frac{R_g}{t_g} + \frac{R_b}{t_b}}$$For a fixed total counting time, the most precise net rate comes from dividing time so that \( t_g/t_b = \sqrt{R_g/R_b} \).
Dead time. After each event a detector is blind for a time τ (hundreds of microseconds for a GM tube, much shorter for scintillation and semiconductor systems). For a non-paralysable detector, true rate n and observed rate m are related by
$$\boxed{n = \frac{m}{1 - m\tau}}$$Efficiency and geometry. Count rate is not activity. Activity (Bq) = count rate / (detection efficiency × fraction of emissions of the measured type). Standards counted in the same geometry remove most of these factors, which is why radio-analytical methods are usually comparative.
Isotope Dilution Analysis (IDA)
The most important quantitative radio-analytical method. Its great advantage: the analyte does not have to be recovered quantitatively, only in a pure (if small) portion whose specific activity can be measured.
Direct isotope dilution
Add a known mass W₁ of labelled analyte with specific activity S₁ to the sample containing an unknown mass Wₓ of the same compound. Mix thoroughly so the label is evenly distributed. Isolate any pure portion and measure its specific activity S₂. Total activity is conserved:
$$S_1 W_1 = S_2 (W_1 + W_x) \quad\Longrightarrow\quad \boxed{W_x = W_1\left(\frac{S_1}{S_2} - 1\right)}$$Variants
| Variant | What is unknown | What is added | Use |
|---|---|---|---|
| Direct IDA | inactive analyte | labelled analyte | amino acids, metals, organics in mixtures |
| Reverse (inverse) IDA | amount of a labelled substance in a sample | known mass of inactive carrier of the same compound | yield of a labelled product, metabolite studies: \( W_x = W_c/(S_x/S_m - 1) \) |
| Double IDA | specific activity of the label itself also unknown | two aliquots with different inactive additions | when the tracer is not calibrated |
| Substoichiometric IDA | — | equal, deliberately less-than-stoichiometric amounts of reagent added to sample and standard, so equal masses are isolated | trace metals; then masses cancel and only activities are compared |
In substoichiometric IDA the same amount of analyte is isolated from both the standard and the spiked sample (because the reagent is the limiting factor), so the ratio of measured activities gives the answer without weighing the isolated fractions.
Radiometric Titrations
A titration in which the end point is found from radioactivity rather than an indicator. One reactant is labelled, and a phase separation (precipitation, solvent extraction) moves activity between phases at the equivalence point.
Example: chloride titrated with ¹¹⁰ᵐAg-labelled Ag⁺. Before the end point every added Ag⁺ precipitates as AgCl, so the solution activity stays near zero. After the end point excess labelled Ag⁺ stays in solution and the solution activity rises linearly. Two straight lines cross at the equivalence volume.
| Labelled species | Solution activity before e.p. | After e.p. | Shape |
|---|---|---|---|
| Titrant (Ag⁺*) | ≈ 0 | rises | flat, then rising |
| Analyte (Cl⁻*) | falls as analyte precipitates | ≈ 0 (constant) | falling, then flat |
| Both labelled | falls | rises | V-shaped |
Radiometric titrations work at low concentrations and in coloured or turbid solutions where indicators fail.
Radioimmunoassay (RIA)
Developed by Rosalyn Yalow and Solomon Berson for insulin; Yalow received the Nobel Prize in Physiology or Medicine for it. RIA is a competitive binding assay:
- A fixed, limited amount of antibody.
- A fixed amount of radiolabelled antigen (often ¹²⁵I-labelled, a γ/X-ray emitter that is easy to count).
- The unlabelled antigen from the sample (or a standard).
Labelled and unlabelled antigen compete for the limited binding sites. The more unlabelled antigen in the sample, the less labelled antigen is bound. After separating bound from free antigen (for example with a second antibody or by precipitation), the bound activity, or the ratio bound/free, is read against a standard curve.
graph LR
A["Sample antigen
(unlabelled)"] --> C{"Limited
antibody"}
B["¹²⁵I-antigen
(fixed amount)"] --> C
C --> D["Separate
bound / free"]
D --> E["Count bound fraction"]
E --> F["More sample antigen
→ lower bound counts"]RIA reaches picogram to nanogram levels of hormones, drugs and vitamins. Non-radioactive immunoassays (ELISA, chemiluminescence) have since replaced it in many routine uses, but the competitive principle is the same. For the antibody side, see Immunotechniques, Histochemistry and Microscopy.
Tracers in Chemistry
Solubility products
Precipitate a salt from a reagent of known specific activity, saturate a solution with it, and count an aliquot of the clear solution. Counts ÷ specific activity = moles dissolved. Hevesy’s lead experiments were of this kind. A worked version is Practice Q6 below.
Mechanisms and structural equivalence
- Thiosulfate. Boil sulfite with elemental ³⁵S to make thiosulfate, S³⁵SO₃²⁻. On decomposition (for example with acid, or via Ag₂S₂O₃ → Ag₂S), the label appears almost entirely in the sulfur or sulfide product and not in the sulfate or SO₂. So the two sulfur atoms of thiosulfate are not equivalent and do not exchange.
- Isotope exchange. Mix two chemical forms of an element, one labelled, and follow how fast the label redistributes. A fast exchange suggests a labile pathway (for example electron transfer between two oxidation states), a slow one an inert system. The fraction exchanged F follows the McKay equation, \( -\ln(1 - F) = R\,t\,(a+b)/(ab) \), where a and b are the concentrations of the two forms and R the exchange rate.
- Self-diffusion in solids and melts, and surface area measurements by exchange, use the same idea.
Stable isotopes are tracers too (¹⁸O in ester hydrolysis, ²H, ¹³C, ¹⁵N), but they are detected by mass spectrometry or NMR rather than counting.
Hot-atom chemistry: the Szilard–Chalmers process
When a nucleus captures a neutron and emits a γ ray, the atom recoils with an energy far larger than a chemical bond energy, so it is usually knocked out of its molecule. In the classic experiment, ethyl iodide is irradiated with neutrons: ¹²⁷I(n,γ)¹²⁸I. The recoiling ¹²⁸I atoms leave the C–I bond and end up as free iodine or iodide, which is shaken out into water, leaving the bulk inactive iodine behind in the organic phase.
Conditions for a useful Szilard–Chalmers separation:
- The recoil energy must exceed the bond energy, so the bond breaks.
- The free radioactive atoms must not exchange rapidly with the target molecules (or the gain is lost).
- The new chemical form must be easy to separate.
The result is a radionuclide of much higher specific activity than the target material, from an (n,γ) reaction that otherwise cannot give carrier-free products (see Nuclear Reactions).
Carriers and purity
| Term | Meaning |
|---|---|
| Isotopic carrier | stable isotope of the same element added so that a trace radionuclide behaves as a weighable quantity (precipitates, adsorbs normally) |
| Hold-back carrier | stable form of an interfering element, added so its radioactive isotopes stay behind |
| Scavenger | a non-specific precipitate (for example Fe(OH)₃) used to sweep out many trace activities |
| Radiocolloid | carrier-free trace activity that adsorbs onto dust and glass like a colloid instead of behaving as a solute |
| Radionuclidic purity | fraction of total activity due to the stated nuclide |
| Radiochemical purity | fraction of the nuclide’s activity present in the stated chemical form |
Radiometric Dating
For a parent P decaying to a stable daughter D, with no daughter present initially and a closed system:
$$D = P\left(e^{\lambda t} - 1\right) \quad\Longrightarrow\quad \boxed{t = \frac{1}{\lambda}\ln\left(1 + \frac{D}{P}\right)}$$| Method | Decay | Half-life | Range, use |
|---|---|---|---|
| Radiocarbon | ¹⁴C → ¹⁴N (β⁻) | about 5730 y | organic material, up to about 50 000 y |
| K–Ar (and ⁴⁰Ar/³⁹Ar) | ⁴⁰K → ⁴⁰Ar (EC branch) | about 1.25 × 10⁹ y | volcanic rocks; argon escapes from melts, resetting the clock |
| Rb–Sr | ⁸⁷Rb → ⁸⁷Sr (β⁻) | very long (tens of billions of years) | rocks, by the isochron method, which removes the need to know initial ⁸⁷Sr |
| U–Pb | ²³⁸U → ²⁰⁶Pb; ²³⁵U → ²⁰⁷Pb | 4.47 × 10⁹ y; 7.0 × 10⁸ y | zircons; two independent clocks (concordia) |
Radiocarbon. ¹⁴C is made in the upper atmosphere by ¹⁴N(n,p)¹⁴C from cosmic-ray neutrons, oxidised to ¹⁴CO₂, and taken up by plants and the food chain. Living matter keeps a steady specific activity (about 15.3 disintegrations per minute per gram of carbon in the classic calibration). After death uptake stops and the activity decays:
$$t = \frac{t_{1/2}}{\ln 2}\ln\frac{A_0}{A}$$Real ages are corrected with calibration curves because the atmospheric ¹⁴C level has varied, and because fossil-fuel CO₂ and atmospheric weapons tests disturbed it. Accelerator mass spectrometry (AMS) counts ¹⁴C atoms directly in milligram samples.
Radiation Units in Brief
| Quantity | SI unit | Older unit |
|---|---|---|
| Activity | becquerel (Bq) = 1 s⁻¹ | curie (Ci) = 3.7 × 10¹⁰ Bq |
| Absorbed dose | gray (Gy) = 1 J kg⁻¹ | rad = 0.01 Gy |
| Equivalent / effective dose | sievert (Sv), weighted for radiation type and tissue | rem = 0.01 Sv |
| Exposure (X, γ in air) | C kg⁻¹ | roentgen |
Memory Tricks
Don’t Confuse
| This | vs | That |
|---|---|---|
| Direct IDA: labelled analyte added to inactive sample | Reverse IDA: inactive carrier added to labelled sample | |
| GM counter: counts only, no energy information | HPGe: high-resolution γ spectrometry | |
| Count rate (cpm) | Activity (Bq): rate corrected for efficiency and emission probability | |
| Radionuclidic purity (which nuclide) | Radiochemical purity (which chemical form) | |
| Isotopic carrier (same element) | Hold-back carrier (interfering element) | |
| RIA: competitive, labelled antigen | Sandwich immunoassays: labelled second antibody, signal rises with analyte | |
| Statistical error depends on counts N | Not on count rate alone |
Common Mistakes
Practice
All questions below are original practice questions written for this page. They are not from any CSIR NET paper. Numerical data given in a question are for that question.
Level 1: Foundation
- A sample gives 10 000 counts. What is the relative standard deviation?
- Which detection method suits a ³H-labelled sample?
- Name the SI unit of absorbed dose.
Answers
- 1/√10 000 = 1%.
- Liquid scintillation counting (the β is too weak to pass a window).
- Gray (1 J kg⁻¹).
Level 2: Part B Style
Practice Q1. 10.0 mg of ¹⁴C-glycine (5000 cpm mg⁻¹) is added to a protein hydrolysate. Pure glycine isolated after mixing has 400 cpm mg⁻¹. The glycine content of the hydrolysate is:
(a) 125 mg (b) 115 mg (c) 12.5 mg (d) 0.80 mg
Answer: (b)
Wₓ = 10.0(5000/400 − 1) = 115 mg. (a) is the total after spiking.
Practice Q2. A sample gives 4000 counts in 10 min and the background 500 counts in 10 min. The net count rate with its standard deviation is:
(a) 350 ± 6.7 cpm (b) 350 ± 5.9 cpm (c) 350 ± 8.6 cpm (d) 400 ± 6.3 cpm
Answer: (a)
Net = 400 − 50 = 350 cpm; σ = √(4000 + 500)/10 = 6.7 cpm. (b) subtracts the variances (√3500/10 = 5.9); (c) adds the standard deviations ((63.2 + 22.4)/10).
Practice Q3. A GM counter with a dead time of 100 µs records 2000 counts s⁻¹. The true count rate is:
(a) 2000 s⁻¹ (b) 2200 s⁻¹ (c) 2500 s⁻¹ (d) 1667 s⁻¹
Answer: (c)
n = m/(1 − mτ) = 2000/(1 − 2000 × 10⁻⁴) = 2000/0.8 = 2500 s⁻¹. At high rates dead-time losses become large; 20% here.
Practice Q4. In a radiometric titration of chloride with Ag⁺ labelled with ¹¹⁰ᵐAg, the activity of the supernatant solution plotted against volume of titrant:
(a) falls linearly and then stays constant (b) stays near zero and then rises linearly (c) rises linearly and then falls (d) rises linearly throughout
Answer: (b)
Before the end point all labelled Ag⁺ precipitates as AgCl; after it, excess labelled Ag⁺ stays in solution. (a) is the shape when the analyte, not the titrant, is labelled.
Level 3: Part C Style
Practice Q5. Charcoal from an archaeological hearth shows 3.8 disintegrations per minute per gram of carbon. Take the value for living material as 15.3 dpm g⁻¹ and t½(¹⁴C) = 5730 y. Which statements are correct?
- The sample is about 11 500 years old.
- The age is a little over two half-lives.
- Counting a 1 g sample for 100 min (with negligible background) gives a relative counting error of about 5%, if the counter efficiency is 100%.
- ¹⁴C in the atmosphere is formed by ¹²C(n,γ)¹³C followed by a second neutron capture.
(a) 1, 2 and 3 only (b) 1 and 4 only (c) 2 and 3 only (d) 1, 2, 3 and 4
Answer: (a) 1, 2 and 3 only
- t = (5730/0.693) ln(15.3/3.8) = 8267 × 1.393 = 1.15 × 10⁴ y. Correct.
- Two half-lives = 11 460 y; the age is slightly larger. Correct.
- Counts = 3.8 × 100 = 380; 1/√380 = 5.1%. Correct.
- Wrong: ¹⁴C comes from ¹⁴N(n,p)¹⁴C.
Practice Q6. AgCl is precipitated with Ag⁺ of specific activity 2.0 × 10⁹ cpm per mol Ag, washed and shaken with water to saturation. A 1.00 mL aliquot of the clear saturated solution gives 26.8 cpm (background-corrected, efficiency included in the specific activity). The K_sp of AgCl is closest to:
(a) 1.3 × 10⁻⁵ (b) 1.8 × 10⁻¹⁰ (c) 1.8 × 10⁻¹⁶ (d) 3.6 × 10⁻¹⁰
Answer: (b)
Moles of Ag in 1.00 mL = 26.8/(2.0 × 10⁹) = 1.34 × 10⁻⁸ mol, so s = 1.34 × 10⁻⁵ mol L⁻¹. K_sp = s² = 1.8 × 10⁻¹⁰. (a) is s, not K_sp; (c) forgets to convert mL to L (s = 1.34 × 10⁻⁸ taken as mol L⁻¹).
Practice Q7. Which statements about radio-analytical methods are correct?
- In direct isotope dilution, losing half the analyte during purification does not change the result, provided the isolated portion is pure.
- In substoichiometric isotope dilution, equal amounts are isolated from sample and standard, so only activities need be compared.
- In the Szilard–Chalmers process, rapid exchange between recoil atoms and the parent molecules is required for high specific activity.
- A NaI(Tl) detector gives better energy resolution than an HPGe detector.
(a) 1 and 2 only (b) 1, 2 and 3 only (c) 2 and 4 only (d) 1 and 3 only
Answer: (a) 1 and 2 only
- Correct: IDA uses specific activity, not total recovery.
- Correct: the limiting reagent fixes the isolated amount.
- Wrong: exchange would carry the label back into the parent compound and destroy the enrichment. It must be slow.
- Wrong: HPGe has far better resolution; NaI(Tl) is chosen for efficiency and cost.
Quick Revision Table
| Idea | Fact |
|---|---|
| γ interactions | photoelectric (photopeak), Compton, pair production > 1.022 MeV |
| Detectors | GM: counts only, long dead time; NaI(Tl): efficient γ; HPGe: best resolution; LSC: ³H, ¹⁴C (quenching) |
| Statistics | σ = √N; relative 1/√N; σ_R = √N/t; σ_net = √(R_g/t_g + R_b/t_b); t_g/t_b = √(R_g/R_b) |
| Dead time | n = m/(1 − mτ) |
| Direct IDA | Wₓ = W₁(S₁/S₂ − 1); no quantitative recovery needed |
| Reverse IDA | inactive carrier added to labelled sample |
| Substoichiometric IDA | equal isolated amounts; compare activities |
| Radiometric titration | labelled titrant: flat then rise; labelled analyte: fall then flat |
| RIA | competitive; ¹²⁵I antigen; bound label falls as analyte rises; Yalow–Berson |
| Tracers | solubility (Hevesy), thiosulfate S non-equivalence, exchange (McKay), self-diffusion |
| Szilard–Chalmers | recoil breaks bond; no fast exchange; separable form; high specific activity |
| Dating | t = (1/λ) ln(1 + D/P); ¹⁴C 5730 y, ≈ 15.3 dpm g⁻¹ living; K–Ar, Rb–Sr isochron, U–Pb |
| Units | Bq, Ci; Gy (J kg⁻¹); Sv |
Key Takeaways
What’s Next
- Activation Analysis: the sample itself is made radioactive, then counted with the detectors described here.
- Revisit the decay law and specific activity: Nuclear Stability and Radioactive Decay.
- Other instrumental methods in the syllabus: Spectroscopic Methods.
- Chapter overview: Nuclear Chemistry.