Determination of Molar Masses
CSIR NET polymer chemistry: end groups, osmometry and A2, light scattering and Zimm plots, viscometry and Mark-Houwink, sedimentation, SEC and MALDI.
- 23 min
On this page · 17 sections
- Prerequisites
- The Hook: Why Nobody Measures a Polymer by Freezing Point
- Absolute and Relative Methods
- 1. End-Group Analysis
- 2. Colligative Methods and Membrane Osmometry
- 3. Static Light Scattering
- 4. Dilute-Solution Viscometry
- 5. Ultracentrifugation
- 6. Size-Exclusion Chromatography (GPC/SEC)
- 7. MALDI-TOF Mass Spectrometry
- Memory Tricks
- Don’t Confuse
- Common Mistakes
- Practice
- Quick Revision Table
- Key Takeaways
- What’s Next
Prerequisites
- The averages themselves (\( \overline{M}_n \), \( \overline{M}_w \), \( \overline{M}_z \), \( \overline{M}_v \)): Molar Mass Averages and Distributions.
- Osmotic pressure and the van ’t Hoff equation: Ideal and Non-Ideal Solutions.
- Sedimentation, diffusion and Rayleigh scattering by particles: Colloids: Classification and Properties.
- Size-exclusion chromatography as a separation: Separation Methods.
The Hook: Why Nobody Measures a Polymer by Freezing Point
Absolute and Relative Methods
An absolute method connects the measured quantity to \( M \) through theory alone (thermodynamics, optics, hydrodynamics). A relative method needs calibration with samples of known \( M \).
| Method | Average obtained | Absolute or relative | Useful range (approximate) |
|---|---|---|---|
| End-group analysis (titration, NMR) | \( \overline{M}_n \) | absolute if the end-group structure is known | up to a few \( 10^4 \) g mol⁻¹ |
| Vapour-pressure osmometry, ebulliometry, cryoscopy | \( \overline{M}_n \) | absolute (VPO is usually calibrated in practice) | low \( M \), up to about \( 10^4 \) |
| Membrane osmometry | \( \overline{M}_n \) | absolute | about \( 2 \times 10^4 \) to \( 10^6 \) |
| Static light scattering | \( \overline{M}_w \) (and \( z \)-average \( R_g \)) | absolute | about \( 10^4 \) upward |
| Sedimentation equilibrium | \( \overline{M}_w \), \( \overline{M}_z \) | absolute | wide |
| Sedimentation velocity + diffusion (Svedberg) | an average depending on how \( s \) and \( D \) are averaged | absolute | wide |
| Dilute-solution viscometry | \( \overline{M}_v \) | relative (needs \( K \) and \( a \)) | wide |
| Size-exclusion chromatography | whole distribution, hence \( \overline{M}_n \), \( \overline{M}_w \), Đ | relative (calibrated), absolute with a light-scattering detector | wide |
| MALDI-TOF mass spectrometry | individual chain masses; \( \overline{M}_n \), \( \overline{M}_w \) for narrow samples | absolute for narrow distributions | up to about \( 10^5 \) for narrow samples |
The ranges are rough guides; instruments and sample chemistry move them. What the exam tests is the average and the absolute/relative column.
1. End-Group Analysis
If every chain carries a known number of titratable or NMR-visible end groups, counting the end groups counts the chains:
$$\overline{M}_n = \frac{(\text{number of that end group per chain}) \times (\text{mass of sample})}{\text{moles of end group}}$$For a linear polyester with one carboxylic acid end per chain, titrated with KOH (56.11 g mol⁻¹), the acid number (mg KOH needed per gram of polymer) gives
$$\overline{M}_n = \frac{56{,}110}{\text{acid number}}\ \text{g mol}^{-1}$$An acid number of 5.61 means \( \overline{M}_n = 10{,}000 \) g mol⁻¹. If both ends are COOH (made with excess diacid), multiply by 2.
Limits. As \( M \) grows the end groups become too dilute to measure accurately, so the method fails above a few \( 10^4 \) g mol⁻¹. It fails completely if branching, cyclisation or side reactions change the number of ends per chain. In \( ^1 \)H NMR the same idea compares the integral of an end group (for example an initiator fragment) with that of the backbone repeat unit.
2. Colligative Methods and Membrane Osmometry
All colligative properties count solute particles, so all give \( \overline{M}_n \). For a polymer solution only osmotic pressure is large enough, except at low \( M \) where vapour-pressure osmometry (VPO) is used.
The virial equation
Polymer solutions are far from ideal even when dilute, because each coil excludes a large volume. The van ’t Hoff law becomes a virial series in the mass concentration \( c \):
$$\boxed{\frac{\Pi}{c} = RT\left(\frac{1}{\overline{M}_n} + A_2c + A_3c^2 + \cdots\right)}$$A plot of \( \Pi/c \) against \( c \) is a straight line at low \( c \):
- Intercept \( (\Pi/c)_{c \to 0} = RT/\overline{M}_n \).
- Slope \( RTA_2 \), giving the second virial coefficient \( A_2 \).
Units: with \( \Pi \) in Pa and \( c \) in kg m⁻³ (numerically g L⁻¹), \( \Pi/c \) is in J kg⁻¹, \( RT \) in J mol⁻¹, and \( \overline{M}_n = RT/(\text{intercept}) \) comes out in kg mol⁻¹.
What \( A_2 \) tells you
Flory–Huggins theory relates \( A_2 \) to the polymer–solvent interaction parameter \( \chi \):
$$A_2 = \frac{\bar{v}_2^{\,2}}{V_1}\left(\frac{1}{2} - \chi\right)$$where \( \bar{v}_2 \) is the specific volume of the polymer and \( V_1 \) the molar volume of the solvent.
| Solvent quality | \( \chi \) | \( A_2 \) | Coil |
|---|---|---|---|
| Good solvent | \( < \tfrac{1}{2} \) | positive | expanded by excluded volume |
| Theta (Θ) solvent, at the Θ temperature | \( = \tfrac{1}{2} \) | zero | unperturbed dimensions, ideal-chain statistics |
| Poor solvent | \( > \tfrac{1}{2} \) | negative | contracted; phase separation on further worsening |
At the Θ condition polymer–polymer and polymer–solvent attractions balance the excluded-volume repulsion, the \( \Pi/c \) plot is flat, and the solution behaves ideally at low concentration. The Θ state is the polymer analogue of the Boyle temperature of a real gas, where the gas second virial coefficient vanishes.
Membrane limits. A semipermeable membrane must pass solvent and hold back every polymer chain. Low-\( M \) chains leak through and lower the measured \( \Pi \), so membrane osmometry overestimates \( \overline{M}_n \) for samples with a low-mass tail. At very high \( M \), \( \Pi \) is too small to measure. VPO (which compares the temperature rise of a solution drop and a solvent drop in solvent vapour) covers the low-\( M \) end.
3. Static Light Scattering
A molecule in the oscillating field of a light wave becomes an oscillating dipole and radiates. For particles much smaller than the wavelength (Rayleigh scattering) the scattered intensity per molecule is proportional to the square of its polarisability, and for a polymer the polarisability is proportional to its mass. So the intensity per molecule goes as \( M^2 \); summed over \( N_i \) molecules, the total is proportional to \( \sum N_iM_i^2 \), and per unit mass concentration to \( \overline{M}_w \).
The Zimm equation
$$\boxed{\frac{Kc}{R_\theta} = \frac{1}{\overline{M}_w}\left(1 + \frac{q^2R_g^2}{3}\right) + 2A_2c}, \qquad q = \frac{4\pi n_0}{\lambda_0}\sin\frac{\theta}{2}$$- \( R_\theta \) is the excess Rayleigh ratio (scattered intensity, normalised for geometry, minus solvent scattering).
- \( K = \dfrac{4\pi^2n_0^2(\mathrm{d}n/\mathrm{d}c)^2}{N_A\lambda_0^4} \) is the optical constant; \( \mathrm{d}n/\mathrm{d}c \), the refractive index increment, must be measured separately. If \( \mathrm{d}n/\mathrm{d}c = 0 \) the polymer is invisible in that solvent.
- \( R_g \) is the radius of gyration (a z-average for a polydisperse sample).
- The \( q^2R_g^2 \) term arises because a coil comparable to \( \lambda/20 \) or larger scatters light from different segments with different phases; the interference reduces scattering at larger angles.
Reading a Zimm plot
Plot \( Kc/R_\theta \) against \( \sin^2(\theta/2) + kc \) (\( k \) an arbitrary spreading constant) and extrapolate twice:
graph TD
A["Measure Kc/R at several angles θ
and several concentrations c"] --> B["Extrapolate each c to θ = 0"]
A --> C["Extrapolate each θ to c = 0"]
B --> D["θ = 0 line: slope gives 2A₂"]
C --> E["c = 0 line: initial slope gives R_g"]
D --> F["Common intercept = 1/M_w"]
E --> FOn the \( c = 0 \) line, \( Kc/R_\theta = (1/\overline{M}_w)[1 + (16\pi^2n_0^2R_g^2/3\lambda_0^2)\sin^2(\theta/2)] \), so
$$\frac{\text{slope}}{\text{intercept}} = \frac{16\pi^2n_0^2R_g^2}{3\lambda_0^2}$$For small molecules or small coils (no angular dependence), a single-angle plot of \( Kc/R \) against \( c \) (the Debye plot) gives \( 1/\overline{M}_w \) and \( 2A_2 \).
Chain dimensions behind \( R_g \)
For a linear chain of \( n \) bonds of length \( l \):
| Model | Mean-square end-to-end distance \( \langle r^2\rangle \) |
|---|---|
| Freely jointed chain | \( nl^2 \) |
| Freely rotating chain, bond angle \( \theta_b \) | \( nl^2\,\dfrac{1 - \cos\theta_b}{1 + \cos\theta_b} \); for the tetrahedral angle this is \( 2nl^2 \) |
| Real chain, unperturbed (Θ) | \( C_\infty nl^2 \), \( C_\infty \) the characteristic ratio (hindered rotation) |
| Real chain, good solvent | larger than unperturbed; \( R_g \propto M^{\nu} \) with \( \nu \approx 0.6 \) |
For any ideal (Gaussian) linear chain, \( \langle R_g^2\rangle = \langle r^2\rangle/6 \), and \( R_g \propto M^{1/2} \). A polyethylene chain of \( 10^4 \) C–C bonds (\( l = 0.154 \) nm) has a freely jointed r.m.s. end-to-end distance of \( 0.154\sqrt{10^4} = 15.4 \) nm, 21.8 nm when freely rotating, yet its fully extended zigzag is about 1.26 µm long. A coil is mostly solvent.
4. Dilute-Solution Viscometry
A dissolved coil increases the viscosity of the solvent in proportion to the volume it sweeps out. In a capillary (Ostwald or suspended-level Ubbelohde) viscometer the flow time \( t \) of a dilute solution is compared with that of the solvent, \( t_0 \); for dilute solutions the density correction is negligible.
| Quantity | Definition | Units |
|---|---|---|
| Relative viscosity | \( \eta_r = \eta/\eta_0 \approx t/t_0 \) | none |
| Specific viscosity | \( \eta_{sp} = \eta_r - 1 \) | none |
| Reduced viscosity | \( \eta_{sp}/c \) | mL g⁻¹ (or dL g⁻¹) |
| Inherent viscosity | \( (\ln\eta_r)/c \) | mL g⁻¹ |
| Intrinsic viscosity | \( [\eta] = \lim_{c\to0}\eta_{sp}/c = \lim_{c\to0}(\ln\eta_r)/c \) | mL g⁻¹ |
Despite its name, \( [\eta] \) is not a viscosity: it has units of inverse concentration and measures the hydrodynamic volume per unit mass of polymer.
Huggins and Kraemer extrapolations
$$\frac{\eta_{sp}}{c} = [\eta] + k_H[\eta]^2c \qquad \text{(Huggins)}$$$$\frac{\ln\eta_r}{c} = [\eta] + (k_H - \tfrac{1}{2})[\eta]^2c \qquad \text{(Kraemer)}$$The Kraemer form follows from expanding \( \ln(1 + \eta_{sp}) = \eta_{sp} - \eta_{sp}^2/2 + \cdots \). Both lines meet at \( [\eta] \) on the axis; the Huggins line rises and the Kraemer line falls (its slope is negative whenever \( k_H < 1/2 \)). Typical \( k_H \) values for flexible polymers in good solvents are around 0.3–0.4.
Mark–Houwink–Sakurada equation
$$\boxed{[\eta] = KM^a}$$\( K \) and \( a \) are constants for a given polymer–solvent–temperature system, obtained by calibrating with fractions of known \( M \) (a plot of \( \log[\eta] \) against \( \log M \) has slope \( a \)). Applied to a polydisperse sample, it returns \( \overline{M}_v \).
| Chain shape / solvent | \( a \) |
|---|---|
| Compact sphere (e.g. a globular protein) | 0 (Einstein: \( [\eta] \) independent of \( M \)) |
| Flexible coil in a Θ solvent | 0.5 |
| Flexible coil in a good solvent | about 0.5–0.8 |
| Semi-rigid chains | 0.8–1 and above |
| Rigid rod | approaching 2 |
The Θ value of 0.5 follows from the Flory–Fox relation \( [\eta] = \Phi\langle r^2\rangle^{3/2}/M \) with \( \langle r^2\rangle \propto M \): \( [\eta] \propto M^{3/2}/M = M^{1/2} \).
5. Ultracentrifugation
In a strong centrifugal field \( \omega^2r \), a macromolecule experiences a net force \( m(1 - \bar{v}\rho)\omega^2r \), where \( \bar{v} \) is its partial specific volume and \( \rho \) the solvent density; the factor \( (1 - \bar{v}\rho) \) is the buoyancy correction.
Sedimentation velocity. The sedimentation coefficient \( s = (\mathrm{d}r/\mathrm{d}t)/\omega^2r \) is measured in svedbergs (1 S = \( 10^{-13} \) s). Combining with the diffusion coefficient \( D \) (both governed by the same friction coefficient \( f = kT/D \)) gives the Svedberg equation:
$$\boxed{M = \frac{sRT}{D(1 - \bar{v}\rho)}}$$Sedimentation equilibrium. At lower speed, sedimentation and back-diffusion balance and the concentration profile becomes exponential in \( r^2 \):
$$\frac{\mathrm{d}\ln c}{\mathrm{d}(r^2)} = \frac{M(1 - \bar{v}\rho)\omega^2}{2RT}$$No friction coefficient appears, so the method is thermodynamically rigorous. For a polydisperse sample it yields \( \overline{M}_w \) (from concentration) and \( \overline{M}_z \) (from concentration gradients). The barometric formula for the atmosphere is the same equation with gravity in place of \( \omega^2r \); see The Boltzmann Distribution.
6. Size-Exclusion Chromatography (GPC/SEC)
SEC separates chains by hydrodynamic volume, not by chemistry. Large coils cannot enter the pores of the gel and elute first; small chains explore more pore volume and elute later. Between the exclusion limit and the total permeation limit, the elution volume \( V_e \) falls roughly linearly with \( \log M \).
Conventional calibration. Run narrow standards (often polystyrene) and plot \( \log M \) against \( V_e \). A concentration detector (refractive index or UV) then gives the mass in each elution slice, and the whole distribution follows, hence \( \overline{M}_n \), \( \overline{M}_w \) and Đ. The result is only “polystyrene-equivalent” unless the sample is polystyrene, because a different polymer of the same \( M \) has a different coil size.
Universal calibration. Since \( [\eta] \) is hydrodynamic volume per unit mass, \( [\eta]M \) is proportional to the hydrodynamic volume of a chain. Benoit and co-workers showed that a plot of \( \log([\eta]M) \) against \( V_e \) is the same for many polymers on a given column. At equal elution volume, with Mark–Houwink constants for each polymer,
$$K_1M_1^{1 + a_1} = K_2M_2^{1 + a_2}$$Adding an on-line multi-angle light-scattering detector makes SEC absolute: each slice gives its own \( M \) directly.
7. MALDI-TOF Mass Spectrometry
In matrix-assisted laser desorption/ionisation, the polymer is co-crystallised with a UV-absorbing matrix and a cationising salt; a laser pulse desorbs intact singly charged chains (often as Na⁺ or K⁺ adducts), and their \( m/z \) is measured by time of flight. For a narrow sample the spectrum resolves individual oligomers:
- Peak spacing = repeat-unit mass (104 for styrene, 44 for ethylene oxide, 100 for methyl methacrylate).
- Absolute peak position = \( nM_0 \) + end groups + cation, so the end groups can be identified.
- Peak intensities \( N_i \) give \( \overline{M}_n = \sum N_iM_i/\sum N_i \) and \( \overline{M}_w \).
For broad distributions (Đ above about 1.2) the method discriminates against high masses, so its averages are reliable mainly for narrow samples. Ionisation techniques are compared on Mass Spectrometry, Electron Spectroscopy and Microscopy.
Memory Tricks
Don’t Confuse
| This | vs | That |
|---|---|---|
| Intrinsic viscosity \( [\eta] \): mL g⁻¹, a hydrodynamic volume per mass | Viscosity \( \eta \): Pa s | |
| Huggins line (\( \eta_{sp}/c \)): rises with \( c \) | Kraemer line (\( \ln\eta_r/c \)): falls with \( c \); same intercept | |
| \( A_2 = 0 \) at the Θ point | \( A_2 = 0 \) means the chain has no interactions (it does; they cancel) | |
| Light scattering: angular slope gives \( R_g \) | Concentration slope gives \( 2A_2 \) | |
| Sedimentation equilibrium: no friction term, gives \( \overline{M}_w \), \( \overline{M}_z \) | Sedimentation velocity: needs \( D \) as well | |
| Conventional SEC calibration: “polystyrene-equivalent” \( M \) | Universal calibration: \( [\eta]M \) matched, real \( M \) | |
| Membrane osmometry: high \( M \), low-\( M \) chains leak | VPO: low \( M \) |
Common Mistakes
Practice
All questions below are original practice questions written for this page. They are not from any CSIR NET paper.
Level 1: Foundation
- Which molar-mass average does static light scattering give?
- What is the value of \( A_2 \) and of the Mark–Houwink exponent \( a \) for a flexible coil in a Θ solvent?
- In SEC, which chains elute first?
Answers
- \( \overline{M}_w \) (scattering per molecule \( \propto M^2 \)).
- \( A_2 = 0 \); \( a = 0.5 \).
- The largest (highest hydrodynamic volume), because they are excluded from the pores.
Level 2: Part B Style
Practice Q1. A membrane-osmometry plot of \( \Pi/c \) against \( c \) at 298 K extrapolates to 24.8 Pa L g⁻¹ at \( c = 0 \). The number-average molar mass (g mol⁻¹) is about:
(a) 100 (b) \( 1.0 \times 10^4 \) (c) \( 1.0 \times 10^5 \) (d) \( 1.0 \times 10^6 \)
Answer: (c)
24.8 Pa L g⁻¹ = 24.8 J kg⁻¹. \( \overline{M}_n = RT/\text{intercept} = 2479/24.8 = 100 \) kg mol⁻¹ \( = 1.0 \times 10^5 \) g mol⁻¹. Option (a) forgets the kg-to-g conversion.
Practice Q2. For a polymer in a given solvent, the Huggins plot gives \( [\eta] = 120 \) mL g⁻¹ and \( k_H = 0.40 \). The slope of the Kraemer plot (\( \ln\eta_r/c \) against \( c \)) in mL² g⁻² is:
(a) +5760 (b) −1440 (c) +1440 (d) −7200
Answer: (b) −1440
Kraemer slope \( = (k_H - \tfrac{1}{2})[\eta]^2 = (0.40 - 0.50)(14{,}400) = -1440 \). Option (a) is the Huggins slope \( k_H[\eta]^2 \).
Practice Q3. Which pair is mismatched?
(a) End-group titration — \( \overline{M}_n \) (b) Sedimentation equilibrium — \( \overline{M}_w \) and \( \overline{M}_z \) (c) Membrane osmometry — \( \overline{M}_w \) (d) Dilute-solution viscometry — \( \overline{M}_v \)
Answer: (c)
Osmometry is colligative and gives \( \overline{M}_n \).
Practice Q4. A polyester with one COOH group per chain has an acid number of 2.80 mg KOH g⁻¹. Its \( \overline{M}_n \) (g mol⁻¹) is about:
(a) 2,000 (b) 10,000 (c) 20,000 (d) 40,000
Answer: (c)
Moles of COOH per gram = \( 2.80 \times 10^{-3}/56.11 = 4.99 \times 10^{-5} \). One end per chain, so \( \overline{M}_n = 1/4.99 \times 10^{-5} = 2.0 \times 10^4 \) g mol⁻¹. Option (d) assumes two acid ends per chain.
Level 3: Part C Style
Practice Q5. Osmotic data for a polymer in a solvent at 298 K: \( \Pi/c \) = 33.46, 35.94, 38.42, 40.90 Pa L g⁻¹ at \( c \) = 2, 4, 6, 8 g L⁻¹. Consider:
- \( \overline{M}_n \approx 8.0 \times 10^4 \) g mol⁻¹.
- The second virial coefficient is about \( 5 \times 10^{-4} \) mol cm³ g⁻², so the solvent is a good solvent.
- At the Θ temperature in this solvent, the four points would lie on a horizontal line.
- The same sample measured by light scattering would give a smaller molar mass.
Which are correct?
(a) 1 and 2 only (b) 1, 2 and 3 only (c) 2 and 4 only (d) 1, 2, 3 and 4
Answer: (b) 1, 2 and 3 only
- Intercept 30.98 J kg⁻¹; \( 2479/30.98 = 80.0 \) kg mol⁻¹. Correct.
- Slope 1.24 = \( RTA_2 \); \( A_2 = 5.0 \times 10^{-4} \) mol m³ kg⁻² = mol cm³ g⁻²; positive means good solvent. Correct.
- \( A_2 = 0 \) at Θ, so \( \Pi/c \) is independent of \( c \) (to this order). Correct.
- Light scattering gives \( \overline{M}_w \ge \overline{M}_n \). Wrong.
Practice Q6. In a Zimm analysis (\( \lambda_0 = 633 \) nm, \( n_0 = 1.50 \)), the common intercept is \( 2.0 \times 10^{-6} \) mol g⁻¹ and the \( c = 0 \) line has slope/intercept = 0.50 per unit \( \sin^2(\theta/2) \). Which statements are correct?
- \( \overline{M}_w = 5.0 \times 10^5 \) g mol⁻¹.
- \( R_g \approx 41 \) nm.
- If the polymer behaved as an ideal Gaussian coil, its r.m.s. end-to-end distance would be about 100 nm.
- The slope of the \( \theta = 0 \) line equals \( A_2 \).
(a) 1, 2 and 3 only (b) 1 and 2 only (c) 2, 3 and 4 only (d) 1, 2, 3 and 4
Answer: (a) 1, 2 and 3 only
- \( 1/2.0 \times 10^{-6} = 5.0 \times 10^5 \). Correct.
- \( R_g^2 = 0.50 \times 3(633)^2/(16\pi^2 \times 2.25) = 1692 \) nm²; \( R_g = 41 \) nm. Correct.
- \( \langle r^2\rangle^{1/2} = \sqrt{6}R_g = 2.449 \times 41 = 101 \) nm. Correct.
- The \( \theta = 0 \) line has slope \( 2A_2 \) (in the units of \( c \)). Wrong.
Practice Q7. Flow times in an Ubbelohde viscometer at 25 °C: solvent 100.0 s; solutions at 0.002, 0.004, 0.006 and 0.008 g mL⁻¹: 116.9, 135.6, 156.1 and 178.3 s. Illustrative Mark–Houwink constants are \( K = 1.1 \times 10^{-2} \) mL g⁻¹ and \( a = 0.725 \). Which statements are correct?
- \( [\eta] \approx 80 \) mL g⁻¹.
- The Huggins constant is about 0.35.
- \( \overline{M}_v \approx 2.1 \times 10^5 \) g mol⁻¹.
- If the same polymer were dissolved in a Θ solvent, \( [\eta] \) would be larger.
(a) 1 and 3 only (b) 1, 2 and 3 only (c) 2 and 4 only (d) 1, 2, 3 and 4
Answer: (b) 1, 2 and 3 only
\( \eta_{sp}/c \) = 84.5, 89.0, 93.5, 97.9 mL g⁻¹: linear with slope 2240 and intercept 80.
- Correct. 2. \( k_H = 2240/80^2 = 0.35 \). Correct. 3. \( (80/0.011)^{1/0.725} = 2.1 \times 10^5 \). Correct.
- In a Θ solvent the coil is less expanded than in a good solvent, so \( [\eta] \) is smaller. Wrong.
Quick Revision Table
| Method | Key equation | Average |
|---|---|---|
| End groups | \( \overline{M}_n = 56{,}110/\text{acid no.} \) (one COOH per chain) | \( \overline{M}_n \) |
| Osmometry | \( \Pi/c = RT(1/\overline{M}_n + A_2c) \) | \( \overline{M}_n \) |
| \( A_2 \) | \( (\bar{v}_2^2/V_1)(\tfrac{1}{2} - \chi) \); zero at Θ | — |
| Light scattering | \( Kc/R_\theta = (1/\overline{M}_w)(1 + q^2R_g^2/3) + 2A_2c \) | \( \overline{M}_w \), \( R_{g,z} \) |
| Chain size | FJC \( \langle r^2\rangle = nl^2 \); \( R_g^2 = \langle r^2\rangle/6 \) (ideal) | — |
| Viscometry | \( \eta_{sp}/c = [\eta] + k_H[\eta]^2c \); \( [\eta] = KM^a \) | \( \overline{M}_v \) |
| \( a \) values | sphere 0, Θ coil 0.5, good coil 0.5–0.8, rod up to 2 | — |
| Svedberg | \( M = sRT/[D(1 - \bar{v}\rho)] \); 1 S = \( 10^{-13} \) s | — |
| Sedimentation equilibrium | \( \mathrm{d}\ln c/\mathrm{d}r^2 = M(1 - \bar{v}\rho)\omega^2/2RT \) | \( \overline{M}_w \), \( \overline{M}_z \) |
| SEC | big elutes first; universal: \( K_1M_1^{1+a_1} = K_2M_2^{1+a_2} \) | distribution |
| MALDI | spacing = repeat unit; best for narrow Đ | \( \overline{M}_n \), \( \overline{M}_w \) |
Key Takeaways
What’s Next
- Step-Growth Polymerisation Kinetics: how extent of reaction controls \( X_n \).
- Chain-Growth Polymerisation Kinetics: kinetic chain length, chain transfer and living polymers.
- Back to the averages: Molar Mass Averages and Distributions.
- Polymer Chemistry: Quick Revision.