Skip to content

Engineering Geology: Dams, Tunnels, Landslides and Seismic Design

CSIR NET Earth Sciences Part C geology: site investigation, RQD, RMR and Q, dam and tunnel geology, slope stability analysis and seismic design.

  • 22 min read
  • Updated
On this page · 15 sections
  1. Prerequisites
  2. The Hook: The Mountain That Fell into a Reservoir
  3. Site Investigation
  4. Rock Mass Classification
  5. Dams
  6. Tunnels
  7. Landslides and Slope Stability
  8. Seismic Design
  9. Memory Tricks
  10. Don’t Confuse
  11. Common Mistakes
  12. Practice
  13. Quick Revision Table
  14. Key Takeaways
  15. What’s Next

Prerequisites

The Hook: The Mountain That Fell into a Reservoir

Site Investigation

Every engineering project follows the same sequence, with the geologist’s input largest at the start:

graph LR
    A[Desk study: maps, reports, imagery] --> B[Field mapping: lithology, structure, weathering, springs]
    B --> C[Geophysics: seismic refraction, resistivity]
    C --> D[Drilling: core logging, RQD, samples]
    D --> E[In-situ and lab tests]
    E --> F[Rock and soil mass classification]
    F --> G[Design, construction, monitoring]
ToolWhat it gives
Seismic refractiondepth to bedrock and weathering profile from P-wave velocity layers; rippability of rock
Electrical resistivityclay layers, water table, saturated shear zones, cavities
Core drillinglithology, discontinuities, core recovery, RQD, samples for testing
Standard penetration test (SPT)blow count \( N \) in soils: density, liquefaction potential
Packer (Lugeon) testrock-mass permeability in a borehole section; 1 Lugeon = 1 litre per minute per metre of test section at 1 MPa (10 bar) pressure, roughly \( 10^{-7} \) m s\(^{-1}\)
Plate load, pressuremeter, flat jackdeformability and in-situ stress
Uniaxial compressive strength (UCS), point load indexintact rock strength; UCS is roughly 20–25 times the point-load index \( I_{s(50)} \)

Weathering grades

The ISRM-type scale: I fresh, II slightly weathered, III moderately weathered (less than half decomposed), IV highly weathered (more than half decomposed), V completely weathered (decomposed to soil, fabric preserved), VI residual soil (fabric destroyed). Foundations for major structures go to grade I–II rock; grades IV–VI behave as soil.

Rock Mass Classification

Intact rock strength rarely governs; discontinuities (joints, bedding, faults, shear zones) do. Three classifications quantify the rock mass.

Rock Quality Designation (RQD)

$$\boxed{\text{RQD} = \frac{\sum \text{lengths of core pieces} \ge 10\ \text{cm}}{\text{total length of core run}}\times 100\%}$$

Measured on core of at least NX size (about 54 mm). Breaks caused by drilling or handling are ignored.

RQD (%)Quality
< 25very poor
25–50poor
50–75fair
75–90good
90–100excellent

RQD ignores joint condition, orientation and water, so it is used inside RMR and Q rather than alone.

Rock Mass Rating (RMR, Bieniawski)

The 1989 version adds ratings for five parameters, then subtracts an adjustment for discontinuity orientation relative to the excavation:

ParameterMaximum rating
Strength of intact rock (UCS or point load)15
RQD20
Spacing of discontinuities20
Condition of discontinuities (roughness, aperture, infill, weathering, persistence)30
Groundwater15
Total before adjustment100
RMRClassDescription
81–100Ivery good
61–80IIgood
41–60IIIfair
21–40IVpoor
< 21Vvery poor

RMR also estimates stand-up time of an unsupported span and rock-mass cohesion and friction angle.

The Q-system (Barton, Lien and Lunde)

$$\boxed{Q = \frac{\text{RQD}}{J_n}\times\frac{J_r}{J_a}\times\frac{J_w}{\text{SRF}}}$$
QuotientRepresentsTerms
RQD/\( J_n \)block size\( J_n \) joint set number: one set 2, two sets 4, three sets 9, four or more 15, crushed rock 20
\( J_r/J_a \)inter-block shear strength\( J_r \) joint roughness (rough undulating high, slickensided planar low); \( J_a \) joint alteration (clean, unaltered low; clay-filled high)
\( J_w \)/SRFactive stress\( J_w \) water reduction factor (1 for dry); SRF stress reduction factor (loosening, squeezing, swelling, rock burst)

Q runs over a logarithmic scale from 0.001 (exceptionally poor) to 1,000 (exceptionally good): 1–4 poor, 4–10 fair, 10–40 good, 40–100 very good. A widely used empirical link between the two systems is

$$RMR \approx 9\ln Q + 44$$

Dams

Dam types and their geological demands

TypeHow it resists waterFoundation needValley shape
Concrete gravityown weightstrong, sound rock at shallow depth; low upliftany; wide valleys acceptable
Arch (single or double curvature)thrust carried into the abutmentsvery strong, unfractured abutmentsnarrow, V-shaped gorge
Buttressinclined slab on buttressesmoderate rockwide valley
Earthfill / rockfill (embankment)mass of fill with impervious coretolerates weaker, deformable foundations; needs local fill materialwide valleys

Indian examples: Bhakra (concrete gravity, Sutlej), Idukki (double-curvature arch, Kerala) and Tehri (earth and rockfill, Bhagirathi).

Structure at the dam site

Attitude of bedsEffect
Dipping upstream, striking parallel to the dam axismost favourable: water pressure pushes the dam against the dip; bedding planes lead back into the reservoir, not under the dam
Dipping downstreamunfavourable: bedding planes are potential sliding surfaces beneath the dam and paths for leakage under it
Horizontal bedsweak interbeds can act as sliding planes; uplift and leakage along bedding
Vertical beds striking along the riverpermeable or weak beds run straight under the dam: leakage paths

Faults and shear zones in the foundation are the commonest problem. They are excavated and backfilled with concrete (dental treatment), grouted and drained, or the axis is moved.

Foundation problems and treatment

ProblemTreatment
Seepage beneath and around the damcurtain grouting (deep, single or multiple rows along the heel), cut-off walls, upstream impervious blanket
Fractured near-surface rockconsolidation grouting (shallow, grid pattern)
Uplift pressure on the basedrainage holes and galleries downstream of the curtain
Solution cavities (karst)mapping by drilling and geophysics, filling and grouting
Swelling clays, weak seamsremoval, shear keys, flattened slopes

The gravity dam: sliding check

Forces per metre length: weight \( W \), horizontal water thrust \( P = \tfrac12\gamma_w H^2 \), and uplift \( U \) (for full uplift, a triangle from \( \gamma_w H \) at the heel to zero at the toe: \( U = \tfrac12\gamma_w H B \)).

$$\boxed{FS_{\text{sliding}} = \frac{\mu\,(W - U)}{P}}$$

(A shear-friction version adds base cohesion times area.) Drainage that cuts uplift is often what turns an unsafe section into a safe one; see Practice Q8.

Reservoir problems

  • Watertightness: leakage through permeable beds, faults, karst or buried channels into adjacent valleys.
  • Reservoir-rim stability: filling raises pore pressure in valley slopes and submerges their toes; rapid drawdown leaves slopes saturated without the support of reservoir water. Vajont is the classic failure.
  • Sedimentation: silt reduces live storage; catchment treatment and sluicing help.
  • Reservoir-induced seismicity (RIS): loading and, more importantly, pore-pressure diffusion along faults can trigger earthquakes on critically stressed faults. Koyna (Maharashtra) in 1967 is the standard Indian example, and seismicity there has continued to correlate with reservoir loading cycles.

Tunnels

Geological factors

FactorEffect
Rock type and RMR/Qsupport type, advance rate, method
Orientation of discontinuitiestunnel axis perpendicular to strike is generally best; axis parallel to the strike of steep beds or joints gives slabbing from the walls and roof
Foldsalong an anticline axis the strata arch over the opening and groundwater drains away from the crest; along a syncline axis the beds form an inverted arch, blocks tend to drop out, and water collects under pressure: the worse case
Faults and shear zonescrushed rock, sudden water and mud inflows, squeezing
Groundwaterinflows, high water pressure, washing out of fault gouge
Squeezing groundweak rocks (phyllite, shale, clay gouge, schist) under high overburden deform plastically into the opening over time
Swelling groundanhydrite, montmorillonite-rich clays absorb water and expand
Rock burstbrittle, massive, strong rock at high stress fails violently
Gas and heatmethane in coal measures, hydrogen sulphide; rock temperature rises with depth along the geothermal gradient

Overburden stress grows as \( \sigma_v = \gamma z \): for \( \gamma = 27 \) kN m\(^{-3}\), 1,000 m of cover gives 27 MPa. When the rock-mass strength is small compared with this stress (a strength-to-overburden-stress ratio of order 1 or less), squeezing is likely; Himalayan tunnels through thrust zones and phyllites routinely meet it. Rock temperature at depth \( z \): \( T = T_0 + (dT/dz)\,z \); with 15 °C at the surface and 25 °C km\(^{-1}\), a tunnel under 1.5 km of cover meets rock at about 52.5 °C.

Overbreak (excavation beyond the design line) is greatest where joints are closely spaced and parallel to the tunnel walls.

Methods and support

  • Drill and blast: flexible for variable rock.
  • Tunnel boring machine (TBM): fast in uniform, moderately strong rock; vulnerable to squeezing ground, fault zones and large inflows.
  • New Austrian Tunnelling Method (NATM): uses the rock mass as part of the support; shotcrete, rock bolts and lattice girders installed promptly, with deformation monitoring guiding further support (an observational method).
  • Support elements: rock bolts and anchors, shotcrete (often fibre-reinforced), steel ribs, concrete lining, forepoling in very poor ground; drainage.

Older empirical schemes include Terzaghi’s rock-load classification and Lauffer’s stand-up time versus unsupported span; RMR and Q have largely replaced them for support design.

Landslides and Slope Stability

Part B covers landslide types (Varnes classification by material and movement), causes, and the infinite-slope factor of safety. Part C adds rock-slope kinematics and limit-equilibrium calculations.

Kinematic analysis on the stereonet (Markland-type tests)

Let \( \psi_f \) be the dip of the slope face, \( \phi \) the friction angle on the discontinuity.

FailureKinematic conditions
Planarplane strikes within about ±20° of the slope face; plane daylights (\( \psi_p < \psi_f \)); plane dips steeper than friction (\( \psi_p > \phi \)); lateral release surfaces exist
Wedgetwo planes intersect in a line that plunges out of the face, less steeply than the face (measured in the direction of the line) and more steeply than \( \phi \)
Topplingsteep discontinuities dipping into the slope, striking roughly parallel to the face; flexural toppling when \( (90° - \psi_p) + \phi \le \psi_f \), where \( \psi_p \) is their dip
Circular (rotational)no controlling discontinuity: soil, heavily fractured or weathered rock, waste dumps; analysed by slip-circle methods (Bishop, Janbu)

Planar failure: limit equilibrium

For a block of weight \( W \) (per metre run) on a plane dipping \( \psi \) with area \( A \), cohesion \( c \), friction angle \( \phi \), water uplift \( U \) on the plane and a horizontal seismic coefficient \( k_h \):

$$\boxed{FS = \frac{cA + (W\cos\psi - U - k_hW\sin\psi)\tan\phi}{W\sin\psi + k_hW\cos\psi}}$$

Water reduces the normal force and hence friction; an earthquake both reduces the normal force and adds a driving force. This is why monsoon rain and earthquakes trigger most landslides in the Himalaya and Western Ghats. A tension crack filled with water adds a further horizontal driving force.

Monitoring and mitigation

MonitoringMitigation
inclinometers (subsurface displacement), piezometers (pore pressure), extensometers and crack meters, GPS and total stations, InSAR, rain gauges for threshold warningssurface and subsurface drainage (most cost-effective), regrading and unloading the head, toe buttresses and retaining walls, rock bolts and anchors, shotcrete and mesh, rockfall barriers, bioengineering, avoidance

The Geological Survey of India is the nodal agency for landslide studies in India, and landslide susceptibility mapping uses the GIS overlay methods of the previous page.

Seismic Design

Ground motion and site effects

  • Peak ground acceleration (PGA) and the response spectrum (peak response of single-degree-of-freedom oscillators of different natural periods) are the design inputs.
  • Site amplification: soft soil over rock amplifies motion, especially near the site’s natural period. For a soil layer of thickness \( H \) and shear-wave velocity \( V_s \):
$$\boxed{T_{\text{site}} = \frac{4H}{V_s}}$$

A 30 m layer with \( V_s = 150 \) m s\(^{-1}\) has \( T = 0.8 \) s. A building whose natural period is near this suffers resonance; a rough rule of thumb puts a building’s period at about 0.1 s per storey, so an 8-storey building is at risk on that site. Mexico City in 1985 is the textbook case of basin-amplified damage to mid-rise buildings.

  • Seismic microzonation maps these site effects, liquefaction potential and landslide hazard at city scale.

Liquefaction

Loose, saturated, clean to silty sands at shallow depth lose strength when cyclic shaking builds up pore pressure until effective stress falls to near zero. Simplified procedure (Seed–Idriss type):

$$\boxed{\text{CSR} = 0.65\,\frac{a_{\max}}{g}\,\frac{\sigma_v}{\sigma'_v}\,r_d} \qquad FS_{\text{liq}} = \frac{\text{CRR}}{\text{CSR}}$$

where \( r_d \) is a depth reduction factor (close to 1 near the surface; \( r_d \approx 1 - 0.00765z \) for \( z \le 9.15 \) m is one common approximation) and CRR, the cyclic resistance ratio, comes from SPT, CPT or shear-wave velocity charts. \( FS_{\text{liq}} < 1 \) means liquefaction is expected. Remedies: densification (vibro-compaction, dynamic compaction), drains, grouting, deep foundations.

Indian code: IS 1893 (Part 1): 2016

ZoneZone factor \( Z \)Intensity broadly associated
II0.10low
III0.16moderate
IV0.24severe
V0.36very severe (north-east, parts of the Himalaya, Kachchh, Andaman and Nicobar)

The design horizontal seismic coefficient is

$$\boxed{A_h = \frac{Z}{2}\,\frac{I}{R}\,\frac{S_a}{g}}$$
  • \( Z/2 \) converts the zone factor (for the maximum considered earthquake) to the design basis earthquake.
  • \( I \) is the importance factor (1.5 for important structures such as hospitals and emergency buildings, 1.0 for ordinary buildings).
  • \( R \) is the response reduction factor, reflecting ductility (for example 5 for a special moment-resisting RC frame, 3 for an ordinary one).
  • \( S_a/g \) is the spectral acceleration coefficient from the design spectrum for the structure’s period and soil type; its plateau value is 2.5.

The design base shear is \( V_B = A_h W \). Ductile detailing of RC structures follows IS 13920.

Design principles

Regular, symmetric plans and elevations; no soft storey (open ground floor for parking); no short columns; strong-column weak-beam ductile frames; adequate shear walls; base isolation for critical facilities; and, first of all, site selection: avoid active fault traces, liquefiable ground and unstable slopes. Dams in high zones receive site-specific seismic hazard studies, and embankment dams are checked for crest settlement and liquefaction of foundation and fill.

Memory Tricks

Don’t Confuse

ThisvsThat
Core recovery: all core recovered / runRQD: only pieces ≥ 10 cm / run
Curtain grouting: deep, seepage controlConsolidation grouting: shallow, strengthens fractured rock
Uplift: water pressure under the baseHydrostatic thrust: water pressure on the upstream face
Planar failure: plane dips out of slope, daylightsToppling: steep planes dip into the slope
Squeezing: time-dependent plastic closure in weak rockRock burst: sudden brittle failure in strong rock
Zone factor \( Z \) (MCE)\( Z/2 \) in \( A_h \) (design basis earthquake)
Magnitude: energy releasedIntensity: effects at a site (governs damage)
Site period \( 4H/V_s \)Building period, about 0.1 s per storey

Common Mistakes

Practice

All questions below are original practice questions written for this page. They are not from any CSIR NET paper.

Level 1: Foundation

  1. What is the joint set number \( J_n \) for three joint sets in the Q-system?
  2. Which dam type needs strong abutments in a narrow gorge?
  3. Which kind of soil is most susceptible to liquefaction?
Answers
  1. 9.
  2. Arch dam.
  3. Loose, saturated, clean to silty sand at shallow depth.

Level 2: Part B Style

Practice Q1. A 3.0 m core run yields natural pieces of 25, 18, 12, 30, 40 and 15 cm, plus many fragments shorter than 10 cm. The RQD and rock quality are:

(a) 47%, poor (b) 47%, fair (c) 100%, excellent (d) 14%, very poor

Answer: (a) 47%, poor

Sum of pieces ≥ 10 cm \( = 25 + 18 + 12 + 30 + 40 + 15 = 140 \) cm. RQD \( = 140/300 = 46.7\% \): in the 25–50% band, poor.

Practice Q2. A rock mass has RQD 60, three joint sets (\( J_n = 9 \)), smooth planar joints (\( J_r = 1.0 \)), unaltered joint walls (\( J_a = 1.0 \)), is dry (\( J_w = 1.0 \)) and has SRF = 1.0. Its Q value and the RMR estimated from \( RMR = 9\ln Q + 44 \) are closest to:

(a) Q = 6.7; RMR = 61 (b) Q = 60; RMR = 81 (c) Q = 0.67; RMR = 40 (d) Q = 6.7; RMR = 44

Answer: (a)

\( Q = (60/9)(1.0/1.0)(1.0/1.0) = 6.67 \) (fair). \( RMR = 9\ln 6.67 + 44 = 9(1.897) + 44 = 61.1 \). (b) forgets \( J_n \).

Practice Q3. At a proposed gravity dam site, the foundation consists of interbedded sandstone and shale striking parallel to the dam axis. Which attitude is most favourable?

(a) beds dipping 15° downstream (b) horizontal beds (c) beds dipping 50° upstream (d) vertical beds striking parallel to the river

Answer: (c)

Upstream-dipping beds put the shale interbeds at an angle the water thrust cannot exploit for sliding and lead seepage back towards the reservoir. Downstream dips create potential sliding planes; horizontal beds allow sliding and leakage along bedding; beds striking along the river carry seepage under the dam.

Practice Q4. A hospital (\( I = 1.5 \)) in seismic zone V (\( Z = 0.36 \)) has a special RC moment-resisting frame (\( R = 5 \)) with \( S_a/g = 2.5 \). If its seismic weight is 20,000 kN, the design base shear is:

(a) 1,350 kN (b) 2,700 kN (c) 5,400 kN (d) 10,800 kN

Answer: (b) 2,700 kN

\( A_h = (0.36/2)(1.5/5)(2.5) = 0.18\times 0.3\times 2.5 = 0.135 \). \( V_B = 0.135\times 20{,}000 = 2{,}700 \) kN. (c) omits the \( Z/2 \) halving.

Level 3: Part C Style

Practice Q5. A rock slope faces 090° (dips east) at 60°. The friction angle on joints is 30°. Four joint sets are mapped (dip direction/dip): J1 095/45; J2 090/70; J3 270/80; J4 180/45. Which statements are correct?

  1. J1 can produce planar failure.
  2. J2 can produce planar failure because it is steeper than friction.
  3. J3 can produce flexural toppling.
  4. J4 cannot produce planar failure on this face.

(a) 1, 3 and 4 only (b) 1 and 2 only (c) 2, 3 and 4 only (d) 1, 2, 3 and 4

Answer: (a) 1, 3 and 4 only
  • 1 true: dip direction within 20° of the face (095 vs 090); \( 30° < 45° < 60° \): it daylights and exceeds friction.
  • 2 false: J2 dips 70°, steeper than the 60° face, so it does not daylight.
  • 3 true: J3 dips steeply into the slope (270 is opposite to 090) and strikes parallel to the face; check \( (90 - 80) + 30 = 40° \le 60° \).
  • 4 true: J4 dips south, 90° away from the face direction, outside ±20°; it can act only as a release surface.

Practice Q6. A rock block on a single plane has weight 4,000 kN per metre run; the plane dips 40° and daylights; \( c = 25 \) kPa, \( \phi = 32° \), area of the plane 30 m\(^2\) per metre. Which statement is correct?

(a) Dry FS is about 1.04; with an uplift of 600 kN/m on the plane it falls to about 0.89; with both uplift and \( k_h = 0.1 \) it falls to about 0.74 (b) Dry FS is about 1.04; uplift does not change FS because it acts normal to the plane (c) Dry FS is about 0.89; with \( k_h = 0.1 \) alone it rises to about 1.04 (d) Dry FS is about 1.36; with uplift it falls to about 1.04

Answer: (a)

\( W\sin 40° = 2{,}571 \) kN; \( W\cos 40° = 3{,}064 \) kN; \( \tan 32° = 0.6249 \); \( cA = 750 \) kN.

  • Dry: \( (750 + 3064\times 0.6249)/2571 = 2665/2571 = 1.04 \).
  • Uplift 600: \( (750 + 2464\times 0.6249)/2571 = 2290/2571 = 0.89 \).
  • Uplift and \( k_h = 0.1 \): normal \( = 3064 - 600 - 257 = 2207 \); resisting \( = 750 + 1379 = 2129 \); driving \( = 2571 + 306 = 2878 \); FS \( = 0.74 \).

(b) is the classic error: uplift acts normal to the plane and that is precisely why it reduces frictional resistance.

Practice Q7. A saturated sand layer has the water table at 2 m depth. At 6 m depth: total unit weight 19 kN m\(^{-3}\) throughout, \( \gamma_w = 9.81 \) kN m\(^{-3}\), \( a_{\max} = 0.24g \), \( r_d = 1 - 0.00765z \), and CRR from SPT = 0.18. Which statements are correct?

  1. \( \sigma_v = 114 \) kPa and \( \sigma'_v \approx 74.8 \) kPa.
  2. CSR is about 0.23.
  3. The layer is expected to liquefy.
  4. Lowering the water table to 6 m would raise CSR at this depth.

(a) 1, 2 and 3 only (b) 1 and 4 only (c) 2, 3 and 4 only (d) 1, 2, 3 and 4

Answer: (a) 1, 2 and 3 only
  • \( \sigma_v = 19\times 6 = 114 \) kPa; \( u = 9.81\times 4 = 39.2 \) kPa; \( \sigma'_v = 74.8 \) kPa. Statement 1 true.
  • \( r_d = 1 - 0.0459 = 0.954 \); CSR \( = 0.65\times 0.24\times (114/74.8)\times 0.954 = 0.227 \). Statement 2 true.
  • \( FS = 0.18/0.227 = 0.79 < 1 \). Statement 3 true.
  • Statement 4 false: with no pore pressure \( \sigma_v/\sigma'_v = 1 \), so CSR falls to about 0.15, and the unsaturated sand would not liquefy anyway. Dewatering is in fact a remedy.

Practice Q8. A triangular concrete gravity dam section is 40 m high with a 30 m base and a vertical upstream face; the reservoir is full to the crest. Take \( \gamma_c = 24 \) kN m\(^{-3}\), \( \gamma_w = 9.81 \) kN m\(^{-3}\), \( \mu = 0.75 \), no cohesion. Which pair (FS against sliding with full uplift; with drains reducing uplift to one-third) is correct?

(a) 0.81; 1.19 (b) 1.38; 1.38 (c) 0.81; 0.81 (d) 1.19; 1.56

Answer: (a) 0.81; 1.19

\( W = \tfrac12(30)(40)(24) = 14{,}400 \) kN/m. \( P = \tfrac12(9.81)(40^2) = 7{,}848 \) kN/m. Full uplift \( U = \tfrac12(9.81)(40)(30) = 5{,}886 \) kN/m.

Full uplift: \( 0.75(14{,}400 - 5{,}886)/7{,}848 = 0.81 \): unsafe.

Uplift reduced to 1,962 kN/m: \( 0.75(12{,}438)/7{,}848 = 1.19 \).

(b) ignores uplift altogether (\( 0.75\times 14{,}400/7{,}848 = 1.38 \)). Drainage galleries are therefore part of the design, not an extra.

Quick Revision Table

IdeaFact or formula
Lugeon1 L min\(^{-1}\) m\(^{-1}\) at 1 MPa; about \( 10^{-7} \) m s\(^{-1}\)
Weathering gradesI fresh … VI residual soil
RQDpieces ≥ 10 cm / run; < 25, 25–50, 50–75, 75–90, 90–100
RMR15 + 20 + 20 + 30 + 15 = 100, minus orientation; classes I–V at 80/60/40/20
Q(RQD/Jn)(Jr/Ja)(Jw/SRF); block size, shear strength, stress
Link\( RMR \approx 9\ln Q + 44 \)
Dam typesgravity (strong base), arch (strong abutments, narrow gorge), embankment (weak foundation)
Favourable dipupstream, strike parallel to axis
Treatmentcurtain grouting, consolidation grouting, drains, dental treatment
Sliding\( FS = \mu(W - U)/P \); \( P = \tfrac12\gamma_wH^2 \); \( U = \tfrac12\gamma_wHB \)
Reservoirleakage, rim stability (Vajont 1963), siltation, RIS (Koyna 1967)
Tunnelsaxis ⟂ strike; anticline better than syncline; squeezing, swelling, rock burst, water, gas, heat
Planar failurestrike within ±20°; \( \phi < \psi_p < \psi_f \)
Topplingsteep planes into slope; \( (90 - \psi_p) + \phi \le \psi_f \)
Planar FS\( [cA + (W\cos\psi - U - k_hW\sin\psi)\tan\phi]/(W\sin\psi + k_hW\cos\psi) \)
Site period\( 4H/V_s \); building about 0.1 s per storey
LiquefactionCSR \( = 0.65(a_{\max}/g)(\sigma_v/\sigma'_v)r_d \); FS = CRR/CSR
IS 1893:2016Z = 0.10, 0.16, 0.24, 0.36; \( A_h = (Z/2)(I/R)(S_a/g) \); \( V_B = A_hW \)

Key Takeaways