Atmospheric Electricity
CSIR NET Earth Sciences Part C meteorology: fair-weather field and ionization, thunderstorm electrification, lightning and the global electric circuit.
- 3
- Topics
- 70
- Min read
- 01 Fair-Weather Electric Field and Atmospheric IonizationStart here CSIR NET Earth Sciences: fair-weather potential gradient, air-Earth current, conductivity, ion production, small and large ions, columnar resistance.
- 02 Thunderstorm Electrification CSIR NET Earth Sciences: thunderstorm charge structure, tripole, graupel-ice non-inductive and inductive charging, convective theory, fields under storms.
- 03 Lightning and the Global Electric Circuit CSIR NET Earth Sciences: lightning types, stepped and dart leaders, return strokes, thunder, sferics, Schumann resonances and the global electric circuit.
- Atmospheric Electricity Short Notes Revise The whole chapter on one page.
Chapter Overview
Atmospheric Electricity is a unit of the meteorology section of Part C in CSIR NET Earth, Atmospheric, Ocean and Planetary Sciences (subject code 702). The official syllabus gives it three lines: the fair-weather electric field and ionization, thunderstorm electrification, and lightning with the global electric circuit. Together they tell one story. The air is a weak conductor because radiation keeps ionizing it; a current therefore leaks down everywhere in fair weather; that leak would kill the field within minutes, so something must be recharging it all the time; and that something is the world’s thunderstorms.
The unit is small but numerical. Part C questions on it use Gauss’s law, Ohm’s law for air, the image method, columnar resistance and the circuit time constant, and they test sign conventions that are easy to get wrong under time pressure. It builds directly on the cloud physics and convection you revise for Physical Meteorology and the descriptive atmosphere of Oceans and Atmosphere.
What You’ll Learn
By the end of this chapter you will be able to:
- State the sign and size of the fair-weather field and potential gradient, and compute the Earth’s surface charge and the space charge from Gauss’s and Poisson’s equations
- Name the sources of ionization by height, solve the ion-balance equation, and explain why aerosol lowers conductivity and raises the potential gradient
- Use columnar resistance, the ionospheric potential and the relaxation time in multi-step numericals
- Draw the thunderstorm tripole at its temperature levels and explain non-inductive graupel–ice, inductive and convective charging
- Sequence a cloud-to-ground flash with typical speeds, currents and temperatures, and interpret sferics, whistlers, Schumann resonances and transient luminous events
- Build the global electric circuit budget (current, resistance, capacitance, time constant) and explain the Carnegie curve
Prerequisites
- Electrostatics (Gauss’s law, Poisson’s equation, image charges) from Electrostatics: Gauss’s Law, Laplace and Poisson
- Clouds, precipitation and the ice phase from Clouds, Precipitation and General Circulation
- Stability, CAPE and deep convection from Vertical Stability and Tropical Convection
Learning Path
The three pages follow the three official topic lines in order: the steady load, the generator, then the discharge and the circuit that joins them.
graph TD
A["1. Fair-Weather Field and Ionization
PG about 100 V/m, ion sources,
conductivity, columnar resistance,
relaxation time"] --> B["2. Thunderstorm Electrification
tripole, graupel-ice charging,
inductive and convective theories,
fields under storms"]
B --> C["3. Lightning and the Global Electric Circuit
leaders, return strokes, thunder,
sferics, Schumann, sprites,
Wilson circuit, Carnegie curve"]
A -->|"why the field needs a generator"| C
C --> D["Quick Revision
one-page sheet"]Topics in This Chapter
| # | Topic | What it covers |
|---|---|---|
| 1 | Fair-Weather Electric Field and Atmospheric Ionization | Sign conventions, potential gradient, Earth’s surface charge, space charge, ionospheric potential; ion sources (radon, gamma, cosmic rays, solar radiation), Pfotzer maximum, ion balance, small and large ions, pollution effect; air-Earth current, columnar resistance, relaxation time; Carnegie curve in brief; instruments |
| 2 | Thunderstorm Electrification | Storm life cycle, tripole and its temperature levels, field at the ground and its reversal; requirements for electrification; non-inductive graupel–ice charging and the reversal temperature, inductive and convective charging, Wilson capture, Lenard, Workman–Reynolds and thermoelectric effects; point discharge, precipitation current, lightning initiation |
| 3 | Lightning and the Global Electric Circuit | Lightning types; stepped leader, attachment, return stroke, dart leader, continuing current; thunder; global flash rate and its geography; detection; sferics, whistlers, Schumann resonances; sprites, elves, jets, TGFs; lightning NOₓ and protection; Wilson’s global circuit, its constants and the Carnegie curve |
| — | Quick Revision | Every number, sign and formula from the unit on one page |
Where each official syllabus line is covered
| Official topic line | Page |
|---|---|
| Fair-weather electric field, ionization | 1 |
| Thunderstorm electrification | 2 (lightning initiation also on 2) |
| Lightning and global electric circuit | 3 (the need for a generator is set up at the end of 1) |
How CSIR NET Asks It
Per the NTA information bulletin for the December 2026 cycle, the Earth, Atmospheric, Ocean and Planetary Sciences paper (3 hours, 200 marks) has:
| Part | Questions given | Attempt | Marks each | Wrong answer |
|---|---|---|---|---|
| A (general aptitude) | 20 | 15 | 2 | −0.5 |
| B (core subject) | 50 | 35 | 2 | −0.5 |
| C (higher-order, analytical) | 80 | 25 | 4 | −1.32 |
Negative marking is 25% in Parts A and B and 33% in Part C. If you answer more than the permitted number in a part, only the first answers up to that number are evaluated. The syllabus lists this unit under Part C (meteorology); the bulletin does not say how many questions come from each unit. The full marking table is on the Earth Sciences overview.
| Question type | Typical content | Where to practise |
|---|---|---|
| Sign and concept | Direction of the fair-weather field, sign of PG, sign of space charge, which ions carry the current, which particle charges which sign at which temperature | Level 1 and 2 on pages 1 and 2 |
| One-step numerical | Surface charge from PG, conductivity from ion data, relaxation time, field below a charge with its image, thunder distance, Schumann frequencies | Level 2 on every page |
| Multi-step numerical | Columnar resistance and ionospheric potential for an exponential profile, tripole fields at a station, global circuit R, C and τ, charge moments and field changes | Level 3 on every page |
| Data interpretation | PG soundings, field-mill traces under a passing storm, laboratory charging tables, Carnegie-type UT curves | Level 3 on pages 1–3 |
| Statement evaluation | Pollution and PG, solar cycle and cosmic rays, precipitation vs convective hypotheses, −CG vs +CG, sprites vs elves | Level 3 on pages 2 and 3 |
Quick Reference: The Chapter at a Glance
| Area | Must-know facts |
|---|---|
| Fair-weather field | Earth negative, air positive; \(E_z \approx -100\) V/m; PG \(= -E_z\); \(\sigma_s = \varepsilon_0E_z\) |
| Ionization | Radon and gamma near the ground over land; cosmic rays aloft and over oceans (Pfotzer maximum about 15–20 km); solar EUV and X-rays above about 60 km |
| Conductivity | \(\sigma = e(n_+\mu_+ + n_-\mu_-)\); small ions only; rises with height; falls with aerosol |
| Column | \(J\) constant with height; \(V_I = JR_c\); \(R_c = H/\sigma_0\) for exponential σ; \(\tau = \varepsilon_0/\sigma\), minutes |
| Thunderstorm | Tripole: upper +, main − near −15 °C, lower + near 0 °C; graupel negative colder than the reversal temperature |
| Ground field under a storm | Reversed; \(2kQ/h^2\) below a point charge; corona limits it to about 10 kV/m |
| Lightning | Stepped leader 10⁵, dart leader 10⁷, return stroke 10⁸ m/s; −CG about 90% of CG; IC most common |
| Global circuit | About 1000–2000 storms, about 1 kA, 250 kV, R ≈ 250 Ω, C ≈ 1.8 F, τ ≈ 7 min; Carnegie maximum near 19 UT |
Related sections: Earth Sciences · Physical Meteorology · Climatology · Physical Sciences
Start Learning