Skip to content

Electronics and Experimental Methods (Advanced) Formula Sheet and Short Notes

One-page CSIR NET revision: curve fitting, chi-square, transducers, conditioning, feedback, noise, shielding, lock-in, box-car, modulation, microwave devices.

  • 7 min read
  • Updated
On this page · 9 sections
  1. Marking in one table
  2. Numbers worth memorising
  3. Curve fitting and chi-square
  4. Transducers and detectors
  5. Conditioning, matching, feedback, control
  6. Noise, filtering, shielding, grounding
  7. Fourier, lock-in, box-car, modulation
  8. High-frequency devices
  9. Last-minute checklist

Every result and trap from Curve Fitting and the Chi-Square Test, Transducers and Detectors, Measurement, Signal Conditioning, Impedance Matching and Feedback, Noise, Filtering, Shielding and Grounding, Fourier Transforms, Lock-in Detection, Box-car Integration and Modulation and High-Frequency Devices, on one page.

Marking in one table

Per the NTA information bulletin for December 2026, Physical Sciences:

PartGivenAttemptCorrectWrongMaximum
B2520+3.5−0.87570
C3020+5−1.25100

This advanced unit is examined in Part C. Full details on the Physical Sciences overview.

Numbers worth memorising

QuantityValue
Johnson noise, 1 kΩ, 300 K4.07 nV/\( \sqrt{\text{Hz}} \)
Thermal noise floor \( k_BT \), 290 K\( -174 \) dBm/Hz
kTC noise, 1 pF, 300 K64 µV rms
Shot noise, 1 µA0.57 pA/\( \sqrt{\text{Hz}} \)
\( 2k_BT/q \) at 300 K52 mV (shot = Johnson)
Pt100 coefficient0.00385 /°C
Metal foil gauge factorabout 2
Si energy per e–h pair3.6 eV
\( 20\log_{10}e \) (shield absorption)8.69 dB per skin depth
Copper skin depth9 mm at 50 Hz, 65 µm at 1 MHz, 2 µm at 1 GHz
\( \chi^2_{0.05} \)3.84 (1), 5.99 (2), 7.81 (3), 9.49 (4), 11.07 (5)
ADC6.02 dB per bit

Curve fitting and chi-square

$$\boxed{m = \frac{N\sum xy - \sum x\sum y}{\Delta}, \quad c = \bar y - m\bar x, \quad \Delta = N\sum x^2 - \left(\sum x\right)^2}$$$$\boxed{\sigma_m^2 = \frac{N\sigma^2}{\Delta}, \quad \sigma_c^2 = \frac{\sigma^2\sum x^2}{\Delta}} \qquad \boxed{\bar x_w = \frac{\sum x_i/\sigma_i^2}{\sum 1/\sigma_i^2}, \ \sigma_{\bar x_w} = \left(\sum\sigma_i^{-2}\right)^{-1/2}}$$$$\boxed{\chi^2 = \sum\frac{(y_i - f_i)^2}{\sigma_i^2}, \quad \nu = N - p, \quad \langle\chi^2\rangle = \nu, \ \text{Var} = 2\nu} \qquad \boxed{\chi^2_{\text{Pearson}} = \sum\frac{(O - E)^2}{E}, \ \nu = k - 1 - p}$$
  • Line passes through \( (\bar x, \bar y) \). Weight \( w = 1/\sigma^2 \).
  • Linearise \( Ae^{bx} \) with \( \ln y \) (weight \( y^2/\sigma_y^2 \)), \( Ax^n \) with log–log.
  • “Linear” fitting means linear in the parameters. Nonlinear fits iterate (Gauss–Newton, Levenberg–Marquardt) and can find local minima.
  • One-parameter \( 1\sigma \): \( \Delta\chi^2 = 1 \).
  • \( \chi^2_\nu \gg 1 \): wrong model or errors too small. \( \chi^2_\nu \ll 1 \): errors too large or over-fitting.

Transducers and detectors

SensorLawNote
RTD\( R_0(1 + \alpha T) \)passive, four-wire
NTC thermistor\( R_0e^{B(1/T - 1/T_0)} \), \( \alpha = -B/T^2 \)kelvin! self-heating
Thermocouple\( S\,\Delta T \), tens of µV/Kactive; cold-junction compensation
Strain gauge\( \Delta R/R = G\varepsilon \)bridge: \( V_{ex}G\varepsilon\times(1/4, 1/2, 1) \)
LVDTAC amplitude \( \propto x \), phase gives signphase-sensitive detection
Hall\( V_H = IB/nqt \)semiconductor; sign of carriers
Piezo\( Q = dF \)no DC; charge amplifier
PMT\( G = \delta^n \)single photons
GM counter\( n = m/(1 - m\tau) \)true > measured
Radiation resolution\( \sigma_E/E = \sqrt{Fw/E} \)Si 3.6 eV, gas about 30 eV
  • Vacuum ladder: Bourdon/capacitance → Pirani/thermocouple (to about \( 10^{-3} \) mbar) → Penning → Bayard–Alpert (UHV). Capacitance manometer is gas-independent.
  • Photon detectors have a cutoff wavelength and are fast; thermal detectors are flat and slow; pyroelectric needs chopped light.
  • Gas counter regions: ionisation chamber → proportional → limited proportional → Geiger–Müller.
  • Accelerometer used below its resonance; seismometer above.

Conditioning, matching, feedback, control

$$\boxed{V_L = V_s\frac{R_L}{R_s + R_L}} \qquad \boxed{Z_{\text{in}} = \left(\frac{N_p}{N_s}\right)^2Z_L} \qquad \boxed{G_{\text{in-amp}} = \left(1 + \frac{2R}{R_G}\right)\frac{R_3}{R_2}}$$$$\boxed{A_f = \frac{A}{1 + A\beta}, \quad \frac{dA_f}{A_f} = \frac{1}{1 + A\beta}\frac{dA}{A}} \qquad \boxed{e_{ss} = \frac{1}{1 + K_pG_0}}$$
Feedback (mixing–sampling)\( Z_{\text{in}} \)\( Z_{\text{out}} \)Amplifier
Series–shunt (voltage-series)↑↓voltage
Shunt–shunt (voltage-shunt)↓↓transresistance
Series–series (current-series)↑↑transconductance
Shunt–series (current-shunt)↓↑current
  • Voltage measurement: \( R_L \gg R_s \). Power: \( R_L = R_s \), 50% efficiency.
  • CMRR error referred to input: \( V_{cm}/\text{CMRR} \).
  • Oscillation (Barkhausen): \( \lvert A\beta\rvert = 1 \), zero net loop phase. Stability needs phase margin.
  • PID: P speeds and leaves offset; I removes offset (wind-up risk); D damps (amplifies noise).
  • ADC: LSB \( = V_{FS}/2^n \); SNR \( \approx 6.02n + 1.76 \) dB. 4–20 mA loop: live zero.

Noise, filtering, shielding, grounding

$$\boxed{v_n = \sqrt{4k_BTRB}} \qquad \boxed{i_n = \sqrt{2qIB}} \qquad \boxed{v_{kTC} = \sqrt{k_BT/C}} \qquad \boxed{F = F_1 + \frac{F_2 - 1}{G_1} + \cdots}$$
  • Noises add in quadrature. Averaging \( N \): SNR \( \times\sqrt N \).
  • 1/f noise: beat it by modulating above the corner frequency.
  • \( F = \text{SNR}_{\text{in}}/\text{SNR}_{\text{out}} \); \( T_e = (F - 1)290 \) K; \( R_{\text{opt}} = e_n/i_n \).
  • RC filter: \( f_c = 1/2\pi RC \), ENBW \( (\pi/2)f_c \); \( n \)th order: \( 20n \) dB/decade. Butterworth flat, Chebyshev sharp, Bessel linear phase.
  • Electric pickup: grounded shield (one end at low frequency). Magnetic pickup: small loop, twisted pair, mu-metal at low frequency. Ground loops: single-point ground, differential input, isolation. HF: ground plane.
  • Shield absorption \( 8.69\,t/\delta \) dB.

Fourier, lock-in, box-car, modulation

$$\boxed{f_s > 2f_{\max}, \quad f_{\text{alias}} = \lvert f - kf_s\rvert} \qquad \boxed{\Delta f = \frac{1}{N\Delta t}} \qquad \boxed{X = R\cos\theta, \ Y = R\sin\theta, \ \text{ENBW} = \frac{1}{4\tau}}$$$$\boxed{P_T = P_c\left(1 + \frac{\mu^2}{2}\right)} \qquad \boxed{\beta = \frac{\Delta f}{f_m}, \quad B_{\text{Carson}} = 2(\Delta f + f_m)}$$
  • Lock-in = multiply by reference + low-pass: a tracking band-pass of width about \( 1/4\tau \). Square-wave reference also sees odd harmonics at \( 1/3, 1/5 \). Reference at \( 2f \) gives second-derivative signals.
  • Box-car: gate + delay + average over pulses; best for low duty cycle; scanning delay recovers the waveform.
  • AM sidebands at \( f_c \pm f_m \), bandwidth \( 2f_m \), sideband share \( \mu^2/(2 + \mu^2) \le 1/3 \). Envelope detector \( 1/f_c \ll RC \le \sqrt{1 - \mu^2}/(\mu\omega_m) \).
  • FM lines \( J_n(\beta) \); constant total power; carrier null at \( \beta \approx 2.405 \).
  • Decay ↔ Lorentzian: natural linewidth \( 1/(2\pi\tau) \) for population lifetime \( \tau \).
  • PCM rate = bits × sampling rate.

High-frequency devices

$$\boxed{\Gamma = \frac{Z_L - Z_0}{Z_L + Z_0}, \quad \text{VSWR} = \frac{1 + \lvert\Gamma\rvert}{1 - \lvert\Gamma\rvert}} \qquad \boxed{Z_{\lambda/4} = \sqrt{Z_1Z_2}} \qquad \boxed{f_{c,mn} = \frac{c}{2}\sqrt{\left(\frac{m}{a}\right)^2 + \left(\frac{n}{b}\right)^2}}$$
  • Reflected power \( \lvert\Gamma\rvert^2 \); return loss \( -20\log\lvert\Gamma\rvert \). Resistive load: \( Z_L = SZ_0 \) (max at load) or \( Z_0/S \) (min at load).
  • \( \lambda/4 \) inverts, \( \lambda/2 \) repeats. Coax \( Z_0 = (60/\sqrt{\varepsilon_r})\ln(b/a) \).
  • Waveguide: TE\( _{10} \) dominant, \( \lambda_c = 2a \); \( \lambda_g = \lambda_0/\sqrt{1 - (f_c/f)^2} \); \( v_pv_g = c^2 \).
  • Klystron: velocity → density modulation (amplifier); reflex klystron oscillator, transit \( (n + 3/4)T \). Magnetron: crossed fields, high-power oscillator. TWT: helix slow wave, broadband amplifier.
  • Gunn: intervalley transfer, bulk NDR, \( f = v_d/L \). IMPATT: avalanche + transit, high power, noisy. Tunnel diode: degenerate doping, fast.
  • PIN: DC-controlled RF resistor. Varactor: voltage-tuned capacitor. Schottky: fast mixer/detector. Diode detector: square law (\( \propto \) power) at low level.
  • HF transistors: \( f_T = g_m/2\pi(C_\pi + C_\mu) \); Miller \( C_\mu(1 + \lvert A_v\rvert) \); HEMT for lowest noise.

Last-minute checklist

Advertisement